System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations

Appendix C

Note The RS-232C port settings can also be changed with the STUP (237) instruction. The RS-232C Port

Settings Changing Flag (A410.15) will remain ON from the time STUP (237) is executed until the set-
tings have actually been changed.

Note The following data is set for no-protocol mode.

Messages Sent and Received with No-protocol Mode

Constant Cycle Time

Set the cycle time to a non-zero value, e.g., to create a consistent motor control cycle. This setting is effective
only when the actual cycle time is shorter than the constant cycle time setting. If the actual cycle time is longer
than the constant cycle time setting, the actual cycle time will remain unchanged.

Note The constant cycle time setting cannot be changed while the Module is in RUN or MONITOR mode.

Watch Cycle Time

If the cycle time exceeds the watch (maximum) cycle time setting, the Cycle Time Too Long Flag (A401.08) will
be turned ON and FQM1 operation will be stopped. This setting must be changed if the normal cycle time
exceeds the default watch cycle time setting of 50 ms.

FLEXIBLE
MOTION
CONTROLLER

RDY
RUN
ERR

PRPHL

COMM1
COMM2

PERIPHERAL

ON

OFF

CM001

2

CN1

RS422

1

40

39

1 2

PORT

RS-232C Port Settings
The standard (default) settings are as follows:
Host Link Mode
1 start bit
7-bit data
Even parity
2 stop bits
9,600 baud rate
If any other serial communications mode is
being used (e.g., NT Link, no-protocol,
peripheral bus, or Host Link), change the
baud rate or other settings as requried.

Send delay

TXD(236)

Data sent

Time

End code

Yes

CR+LF

No

Start code

No

Yes

Received bytes

Data: 1 to 256 bytes

Data

Data

ED

CR+LF

Data

Data

Data

ED

ST

ST

ST

CR+LF

Data

Constant

(minimum)

time