Pulse Inputs

Section 7-5

7-5

Pulse Inputs

7-5-1

Applicable Models

7-5-2

Outline

The FQM1-MMP21 and FQM1-MMA21 Motion Control Modules can receive
pulse inputs. The following table shows the processes that can be performed
by combining the pulse input function with the high-speed counters to count
pulse signals from a rotary encoder or other device and perform processing
based on the counter PV.

Note

Interrupts cannot be generated for range comparisons. Only bit patterns are
output.

The high-speed counter PV movement during a fixed time interval (equivalent
to the travel distance) and the high-speed counter’s frequency can also be
monitored as required.

7-5-3

Specifications

Model

Functions

FQM1-MMP21

Motion Control Module for Pulse I/O

FQM1-MMA21

Motion Control Module for Analog I/O

Process

Description

Target value comparison
interrupts

An interrupt task is executed when the high-speed
counter PV equals a preset target value.

Bit pattern outputs for
range comparisons

When the high-speed counter PV is within a specified
range, the user-set bit pattern specified in the compari-
son table is output internally.

Measurement
modes 1 and 2

Movement in the high-speed counter or input pulse
counting speed can be displayed while monitoring the
high-speed counter PV.

High-speed counter PV
latch

High-speed counters 1 and 2 each have a latch register.
Two latch inputs can be used to capture the high-speed
counter PVs at high speed.

Item

Specification

Number of counters

2

Pulse input operation mode
(Set in System Setup.)

Phase differential

Increment/decrement

Pulse + direction

Input pin
numbers

High-speed
counter 1

High-speed
counter 2

24 V: 1 (5)
LD: 3 (5)

24 V: 2 (6)
LD: 4 (6)

Phase A

Increment pulse

Pulse

24 V: 7 (11)
LD: 9 (11)

24 V: 8 (12)
LD: 10 (12)

Phase B

Decrement pulse

Direction pulse

24 V: 13 (17)
LD: 15 (17)

24 V: 14 (18)
LD: 16 (18)

Phase Z

Reset pulse

Reset pulse

Input method

Phase differential

Ч1,

Ч2, or ×4 (switchable)

Single-phase

×2

Single-phase + direc-
tion

Set in the System Setup.

(Set input for pulse input counter 1 and counter 2.)

Counting speed (Set separately for each
port in the System Setup.)

50 kHz (default) or 500 kHz (2 MHz when using phase differential

×4)

Counter operation

Linear Counter or Circular Counter (Set in the System Setup.)