Module i/o refresh times, 291 programming appendix a – Omron HOME SECURITY SYSTEM - MOTION SENSOR FQM1-MMA21 User Manual

Page 314

Advertising
background image

291

Programming

Appendix A

4.

I/O Refreshing

5.

Cyclic Refreshing

6.

Sync Bus Refreshing

7.

Peripheral Service

Module I/O Refresh Times

Cyclic Refresh Time in the Coordinator Module

Cyclic Refresh Time in Motion Control Modules

Details

Processing time and fluctuation cause

The built-in I/O and special inputs (pulse/analog) on the
Motion Control Module are refreshed.

MMP21: 48

µs

MMA21: 135

µs

Motion Control Module I/O refresh time

Details

Processing time and fluctuation cause

Cyclic refresh with the Coordinator Module

21

µs

Details

Processing time and fluctuation cause

The sync bus between the Coordinator Module and
Motion Control Modules is refreshed.

60

µs

Details

Processing time and fluctuation cause

Event servicing with Motion Con-
trol Modules

40

µs + Event service time

Event service time includes event servicing for DM area transfers requested by
the Coordinator Module, event processing for requests from the CX-Program-
mer, etc.

Model

I/O refresh time

FQM1-MMP21/MMA21

40

µs per Module

Model

I/O refresh time

FQM1-MMP21/MMA21

21

µs