Omron HOME SECURITY SYSTEM - MOTION SENSOR FQM1-MMA21 User Manual

Page 99

Advertising
background image

76

Wiring Servo Relay Units

Section 3-4

Nomenclature and Functions

1,2,3...

1.

Motion Control Module 40-pin Connector
Connects to the 40-pin connector on the Motion Control Module.

2.

Motion Control Module 34-pin Connector
Connects to the 26-pin connector on the Motion Control Module. The Mo-
tion Control Module general-purpose I/O is allocated to the clamp terminal
block.

3.

Servo Driver Connectors
Connects to two Servo Drivers.

4.

RS-422 Connector

5.

Screw-less, Clamp Terminal Block (80 Terminals)
The clamp terminal block is used for the Motion Control Module general-
purpose I/O and the Servo Driver control signals. It is also used for external
device connections, such as analog inputs and latch signal inputs.

1. Motion
Control
Module 40-pin
connector

2. Motion
Control
Module 34-pin
connector

6. Signal switches

4. RS-422 connectors

7. Terminating resistance switch

8. Servo Driver # 2
phase B switch

8. Servo Driver # 1
phase B switch

3. Servo Driver #2
connector

3. Servo Driver #1
connector

Mounting hole
(Can be mounted
to DIN Track.)

5. Screw-less Clamp Terminal
Block (40 terminals each on
upper and lower tiers)

Motion Control

Module

Corresponding

connecting cable

Servo Driver

cable

Servo Driver

FQM1-MMP21

XW2Z-

@@@J-A28

XW2Z-

@@@J-A30

XW2Z-

@@@J-B9

W-series Servo
Driver

XW2Z-

@@@J-B10 SMARTSTEP

FQM1-MMA21

XW2Z-

@@@J-A28

XW2Z-

@@@J-A31

XW2Z-

@@@J-B13 W-series Servo

Driver

Pin No.

Signal

1

TXD

2

TXD+

3

---

4

---

5

---

6

RXD

7

---

8

RXD+

9

---

Case

FG