4 wiring servo relay units, Wiring servo relay units – Omron HOME SECURITY SYSTEM - MOTION SENSOR FQM1-MMA21 User Manual

Page 98

Advertising
background image

75

Wiring Servo Relay Units

Section 3-4

Applicable Connector-Terminal Block Conversion Units

Recommended Wire
Size

The recommended size for cable wires is AWG24 to AWG26 (0.2 to

0.13 mm

2

). Use a cable with an outer diameter of less than 1.61 mm.

3-4

Wiring Servo Relay Units

XW2B-80J7-1A Servo Relay Units can be used to connect Motion Control
Modules and Servo Drivers.

A Servo Relay Unit simplifies wiring, e.g., from a Motion Control Module to
two Servo Drivers, for general-purpose I/O wiring, such as for switches and
sensors, and for RS-422A line wiring.

The Servo Relay Unit uses a special cable and simplifies connections from
one Motion Control Module to two Servo Drivers, such as the W Series and
SMARTSTEP Series.

Servo Relay Units can be mounted to DIN Track or on the panel itself.

Connecting Cable

Connector-Terminal Block

Conversion Unit

Number of

pins

Size

XW2Z-

@@@K

XW2D-40G6

40 pins

Miniature

XW2B-40G5

Standard

XW2B-40G4

Standard

XW2Z-

@@@J-A28

XW2D-34G6

34 pins

Miniature

IN

C

se

rvo1

AB

S _C

W

-

0

19

Advertising