Debugging instructions, Failure diagnosis instructions, Other instructions – Omron HOME SECURITY SYSTEM - MOTION SENSOR FQM1-MMA21 User Manual

Page 395: Block programming instructions

Advertising
background image

372

Auxiliary Area Allocations

Appendix D

Serial Communications Instructions

Note When a double-length operand is used, add 1 to the value shown in the length column in the above

table.

Debugging Instructions

Note When a double-length operand is used, add 1 to the value shown in the length column in the above

table.

Failure Diagnosis Instructions

Note When a double-length operand is used, add 1 to the value shown in the length column in the above

table.

Other Instructions

Note When a double-length operand is used, add 1 to the value shown in the length column in the above

table.

Block Programming Instructions

Instruction

Mnemonic

Code

Length
(steps)

(See

note.)

ON execution

time (

µs)

Hardware

implementation

Conditions

TRANSMIT

TXD

236

4

24.1

---

Sending 1 byte

342.6

---

Sending 256 bytes

RECEIVE

RXD

235

4

36.2

---

Storing 1 byte

348.9

---

Storing 256 bytes

CHANGE SERIAL
PORT SETUP

STUP

237

3

441.1

---

---

Instruction

Mnemonic

Code

Length
(steps)

(See

note.)

ON execution

time (

µs)

Hardware

implementation

Conditions

TRACE MEMORY
SAMPLING

TRSM

045

1

34.6

---

Sampling 1 bit and 0 words

148.3

---

Sampling 31 bits and 6 words

Instruction

Mnemonic

Code

Length
(steps)

(See

note.)

ON execution

time (

µs)

Hardware

implementation

Conditions

FAILURE ALARM

FAL

006

3

157.1

---

Recording errors

56.0

---

Deleting errors (in order of priority)

457.0

---

Deleting errors (all errors)

53.6

---

Deleting errors (individually)

SEVERE FAILURE
ALARM

FALS

007

3

---

---

---

Instruction

Mnemonic

Code

Length
(steps)

(See

note.)

ON execution

time (

µs)

Hardware

implementation

Conditions

SET CARRY

STC

040

1

0.15

Yes

---

CLEAR CARRY

CLC

041

1

0.15

Yes

---

Instruction

Mnemonic

Code

Length

(steps)

(See

note.)

ON execution

time (

µs)

Conditions

BLOCK PROGRAM
BEGIN

BPRG

096

2

20.3

---

---

BLOCK PROGRAM
END

BEND

801

1

17.2

---

---

Advertising