System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations

Appendix C

Note Always set the Circular Maximum Count when setting any of the circular operation modes.

FQM1-MMA21 Motion Control Modules with Analog I/O

CX-Programmer: Pulse Input Tab Page

Address

Bits

Function

Remarks

When setting

is read

+320

00 to 03 High-speed

counter 1 (Counter
1)

Input method

0 hex: Phase differential x1
1 hex: Phase differential x2
2 hex: Phase differential x4
3 hex: Increment/decrement pulse inputs
4 hex: Pulse + direction inputs

At power ON

04 to 07

Reset method

0 hex: Software reset
1 hex: Phase Z and software reset

08 to 11

Counting speed

0 hex: 50 kHz
1 hex: 500 kHz

12 to 15

Counter operating
mode (Counter opera-
tion)

0 hex: Linear counter
1 hex: Circular counter
2 hex: Absolute linear counter (CW

−)

3 hex: Absolute circular counter
4 hex: Absolute linear counter (CW+)

+321

00 to 03

Counter data to moni-
tor (Counter data dis-
play)

0 hex: Do not monitor (Non-monitor)
1 hex: Counter PV changes (Counter movements
(mode 1))
2 hex: Frequency (mode 2)
Note The frequency (mode 2) can be set only for
high-speed counter 1.

04 to 15

Reserved

+322

00 to 15

Sampling time (for
mode 1 only)

Sets the sampling time for monitoring counter PV
changes (mode 1)
0000: Cycle time
0001 to 270F hex: 1 to 9,999 ms
(unit: 1 ms)

Note This setting is valid only when the Counter
Data Display (bits 00 to 03 of +321) is set to 1 hex
(mode 1).

+323

00 to 03 High-speed

counter 2 (Counter
2)

Input method

Same as for high-speed counter 1 except that fre-
quency measurement (Counter data to monitor, bit
00 to 03 of +324: 02 hex) cannot be set for high-
speed counter 2.

04 to 07

Reset method

08 to 11

Counting speed

12 to 15

Counter operating
mode (Counter opera-
tion)

+324

00 to 03

Counter data to moni-
tor (Counter data dis-
play)

04 to 15

Reserved

+325

00 to 15

Sampling time (for
mode 1 only)

+326 to 327 00 to 15 High-speed

counter 1 (Counter
1)

Circular maximum
count

Sets the maximum circular counter value.
Range: 0000 0001 to FFFF FFFF hex

Absolute encoder res-
olution

0000 0001 to 0000 FFFF hex
Note Set this value in pulses/rotation according to
the encoder dividing ratio set for the Servo Driver
and the input method multiplier set for the Module.
Example: If the Servo Driver setting is 1,000 and
the Module setting is x4, set FA0 (4,000).

+328 to 329 00 to 15 High-speed

counter 2 (Counter
2)

Circular maximum
count

Same as for high-speed counter 1.

Absolute encoder res-
olution