6-2 watch cycle time function, 6-3 cycle time monitoring function, Watch cycle time function – Omron HOME SECURITY SYSTEM - MOTION SENSOR FQM1-MMA21 User Manual

Page 139: Cycle time monitoring function

Advertising
background image

116

Cycle Time Settings

Section 5-6

Note

When the constant cycle time function is enabled for the Motion Control Mod-
ule in ASync Mode, the Motion Control Module's cycle time will be constant.

5-6-2

Watch Cycle Time Function

If the real cycle time is longer than the set watch cycle time, operation will stop
for all Modules and the Cycle Time Too Long Flag (A401.08) in the Auxiliary
Area will turn ON.

System Setup

!Caution If the Cycle Time Too Long Flag turns ON for one Module in Sync Mode, the

Cycle Time Too Long Flag will turn ON for all Modules.

Note

The settings are made using CX-Programmer Ver. 5.0

@ menus.

Cycle Time Too Long Flag

5-6-3

Cycle Time Monitoring Function

Every cycle, the maximum cycle time is stored in A206 and A207 and the PV
is stored in A208 and A209 in the Auxiliary Area.

Auxiliary Area Words

The average cycle time for the last 8 scans can also be read from the CX-Pro-
grammer.

Note

The FQM1 can skip program areas that do not need to be executed by using
the JMP-JME instructions to shorten cycle times.

Coordinator
Module

Motion
Control
Module

Constant cycle time

Constant cycle time

Waiting for I/O refresh
to become constant

Waiting for I/O refresh
to become constant

Processing

Processing

I/O refresh

I/O refresh

Waiting to
synchronize

Waiting to
synchronize

Constant I/O
refresh timing

Constant I/O
refresh timing

Tab page

Name

Details

Default

Timer/Peripheral Servic-
ing or Cycle Time

Cycle Time

0.1 to 100.0 ms
(unit: 0.1 ms)

Variable

Watch Cycle Time 1 to 100 ms

(unit: 1 ms)

50 ms

Name

Address

Details

Cycle Time Too Long
Flag

A401.08

Turns ON if the cycle time PV exceeds the
Watch Cycle Time in the System Setup.

Name

Addresses

Meaning

Maximum Cycle
Time

A206 to A207

The maximum cycle time value is stored in
binary each cycle. The time is measured in
0.01-ms units.

Cycle Time PV

A208 to A209

The cycle time PV is stored in binary each
cycle. The time is measured in 0.01-ms
units.

Advertising