Omron HOME SECURITY SYSTEM - MOTION SENSOR FQM1-MMA21 User Manual

Page 65

Advertising
background image

42

Motion Control Modules

Section 2-4

Pulse Inputs and Analog
I/O Specifications

FQM1-MMA21 (Analog I/O)

Item

Specifications

Pulse
inputs

Number of counters 2

Counter operations

Linear counter, circular counter

Input signals

Two words each for phase A, phase B, and phase Z.

Signal levels

CH1: 24 V DC, line-driver
CH2: Line-driver

Input method

Phase differential

×1

Phase differential

×2

Phase differential

×4

Increment/decrement
Pulse + direction

Counting speed

Voltage

50 kHz

Line-driver

50 k Hz/500k Hz (phase
differential

× 4, 2 MHz)

Absolute Servo
Driver interfaces

2
SEN output specifications: 5 V PNP output, output
current 5 mA
When SEN signal is output to Servo Driver, Servo
Driver will transmit the number of encoder's rotations
to this Module. After that, it transmits pulse train cor-
responding to displacement of the number of rota-
tions to the Module.

Analog
input

Number of analog
inputs

1

Input signals

Voltage inputs:

−10 to 10 V
0 to 10 V
1 to 5 V
0 to 5 V

Current inputs:
4 to 20 mA

Resolution

−10 to 10 V:

14 bits (1/16,000)

0 to 10 V:

13 bits (1/8,000)

0 to 5 V:

12 bits (1/4,000)

1 to 5 V/4 to 20 mA: 12 bits (1/4,000)

Accuracy (FS)

Voltage input:

± 0.2% (23 ± 2°C)

± 0.4% (0 to 55°C)

Current input:

± 0.4% (23 ± 2°C)

± 0.6% (0 to 55°C)

Conversion speed

40

µs max./input

Total: 1.5 ms max.

Analog
outputs

Number of outputs

2

Output signal

−10 to 10 V, 0 to 10 V, 1 to 5 V, 0 to 5 V

Resolution

−10 to 10 V: 14 bits (1/1,0000)
0 to 10 V:

12 bits (1/4,000)

0 to 5 V:

12 bits (1/4,000)

1 to 5 V:

12 bits (1/4,000)

Accuracy (FS)

± 0.3% (23 ± 2°C) ± 0.5% (0 to 55°C)

Conversion speed

40

µs max./output

Total: 200

µs max.