1-6 no-protocol communications (rs-422a port), No-protocol communications (rs-422a port) – Omron HOME SECURITY SYSTEM - MOTION SENSOR FQM1-MMA21 User Manual

Page 159

Advertising
background image

136

Serial Communications

Section 6-1

6-1-6

No-protocol Communications (RS-422A Port)

RS-422A Settings

Note

The settings are made using CX-Programmer Ver. 5.0

@ menus.

Item

Settings

Default

Enabled

Mode

No-protocol

Serial Gateway

Each cycle

Delay

0 to 99,990 ms (unit: 10 ms)

0 ms

End code

00 to FF hex

00 hex

Start code

00 to FF hex

00 hex

Received bytes

01 to FF hex: 1 to 255 bytes

256 bytes

Use of end code Received bytes or CR+LF

Received bytes

Use of start
code

No
Yes

No

FQM1

RS-422A

RS-232C

RS-232C port

No-protocol

Coordinator Module

Coordinator Module ladder program

TXD/RXD
instructions

RS-422A port

No-protocol

General-
purpose
external
device

Servo Driver

Servo Driver