Omron HOME SECURITY SYSTEM - MOTION SENSOR FQM1-MMA21 User Manual

Page 180

Advertising
background image

157

Pulse Inputs

Section 7-5

Monitoring High-speed
Counter Movement
(Mode 1)

This function monitors the change in a high-speed counter’s PV (travel dis-
tance) regularly at the preset sampling period. The sampling period can be
set between 1 and 9,999 ms.

If the sampling time is set to 0, the change will be sampled once each cycle.
The change in the high-speed counter PV (travel distance) is stored in A604
and A605 (high-speed counter 1) or A606 and A607 (high-speed counter 2).
Status Flags A608.06 and A609.06 can be checked to determine whether or
not change is being measured.

Note

(1) The change (per sampling period) is refreshed during the Motion Control

Module’s I/O refreshing.

(2) The change in the high-speed counter PV’s is output as an absolute val-

ue.

The pulse input’s counter data display must be set to counter movements
(mode 1) in the System Setup in advance. The sampling period must also be
set in the System Setup.

Word

Bits

Function

Details

A604 and
A605

00 to 15

High-speed Counter 1
Monitor Data

Contains the change in high-speed
counter 1.

The change in the high-speed
counter PV during the specified sam-
pling period is stored in 8-digit hexa-
decimal (0000 0000 to FFFF FFFF).

A606 and
A607

00 to 15

High-speed Counter 2
Monitor Data

Contains the change in high-speed
counter 2.

The change in the high-speed
counter PV during the specified sam-
pling period is stored in 8-digit hexa-
decimal (0000 0000 to FFFF FFFF).

A608

06

High-speed Counter 1
Status Flag

Measuring Flag

OFF: The high-speed counter move-

ment measurement operation
is stopped.

ON:

The high-speed counter move-

ment is being measured.

A609

06

High-speed Counter 2
Status Flag

Measuring Flag

OFF: The high-speed counter move-

ment measurement operation
is stopped.

ON:

The high-speed counter move-

ment is being measured.

Tab page

Function

Details

Pulse input

Counter 1

Counter data
display

1 hex:

Counter movements (mode 1)

Sampling time
(mode 1)

Set the sampling time when mea-
suring counter movement.

0000: Cycle time
0001 to 270F hex: 1 to 9999 ms
(unit: 1 ms)

Counter 2

Counter data
display

1 hex:

Counter movements (mode 1)

Sampling time
(mode 1)

Set the sampling time when mea-
suring counter movement.

0000: Cycle time
0001 to 270F hex: 1 to 9999 ms
(unit: 1 ms)

Advertising