201

Functions for Servo Drivers Compatible with Absolute Encoders

Section 7-7

• Example 1

A value between 0 and 65,534 is set in the Servo Driver, the System
Setup’s Counter 1 Counter operation is set to an absolute linear (CW

−)

counter, and the Servo Driver’s reverse rotation mode setting
(Pn000.0) is set to 0 (+ command for rotation in CCW direction).

• Example 2

The System Setup’s Counter 1 Counter operation is set to an absolute
linear (CW

+) counter and the Servo Driver’s reverse rotation mode set-

ting (Pn000.0) is set to 1 (+ command for rotation in CW direction).

Note

When using an absolute linear (CW

−) counter, the phase-B phase can be

inverted with an FQM1-series Servo Relay Unit so that the Servo Driver’s
operation matches the pulse output operation.

7-7-4

Counter Operation

Counting Operation

The counting operations performed in the absolute linear (CW

−), absolute lin-

ear (CW+), and absolute circular counters are the same as the pulse input
function’s linear and circular counters. However, the normal linear counter
does not have the function that receives the rotation data stored in a Servo
Driver compatible with an absolute encoder.

Counter Operation
Details

The details of the absolute linear (CW

−), absolute linear (CW+), and absolute

circular counters are as follows:

Absolute Linear (CW

)

Counter (CCW Rotation
for + Count)

When an absolute encoder rotates in reverse, the pulse information is
counted with a linear counter. Use this mode when the Servo Driver’s reverse
rotation mode parameter has been set to positive (+) command for CCW rota-
tion.

Absolute Linear (CW+)
Counter (CW Rotation for
+ Count)

When an absolute encoder rotates forward, the pulse information is counted
with a linear counter. Use this mode when the Servo Driver’s reverse rotation
mode parameter has been set to positive (+) command for CW rotation.

0

PV of +65,534

ABS PV is a positive value.

0

PV of

−65,534

ABS PV is a negative value.