Example 3:
Latching High-speed
Counter PV

In this example, pulse input 1 operates a high-speed counter, the high-speed
counter PV is latched, and the captured high-speed counter PV is read. When
the Latch Input 1 Enable Bit is ON and the latch input 1 is turned OFF

→ON

externally, the high-speed counter PV is captured to the latch register and the
Count Latched Flag is turned ON during the next I/O refreshing.

The Count Latched Flag is used as a trigger for the PRV(881) instruction to
read the captured high-speed counter PV and the Count Latched Flag is then
turned OFF.

If latch input 1 is turned ON again while the Count Latched Flag is still ON
(before the captured PV has been read by the PRV(881) instruction), the old
captured PV will be refreshed with the new captured PV.

0

ON

OFF

OFF

ON

OFF

ON

Latch Input 1
Enable Bit

Latch input 1

High-speed
Counter PV

Latch register
value 1

PRV instruction
execution

PRV instruction
execution

Count Latched
Flag

A610.08

A608.08

A610.08

PRV

#0001
#0002

D00000

PRV

#0001
#0002

W000

Clear Latch

Start Latch

Latch Input 1
Enable Bit

Count Latched
Flag

Dummy read of
latch register

Read latched high-speed
counter PV.

Latch Input 1
Enable Bit