3-4 cyclic refresh area allocations, Cyclic refresh area allocations – Omron HOME SECURITY SYSTEM - MOTION SENSOR FQM1-MMA21 User Manual

Page 131

Advertising
background image

108

Cyclic Refresh

Section 5-3

5-3-4

Cyclic Refresh Area Allocations

CM: Coordinator Module
MM: Motion Control Module

CIO 0105

00 to 07 MM Output Refresh Area

(This MM to CM)

Data from this area is allo-
cated to the Coordinator Mod-
ule's CM Input Refresh Area
(MM to CM).

Reserved

08

Reserved

09

Cycle time over warning

OFF: No error
ON: MM cycle time exceeded 10 ms.

10

Non-fatal error for this Motion Control Module (including FAL
instructions)

OFF: No non-fatal error
ON: Non-fatal error

11

Fatal error for this Motion Control Module (including FALS instruc-
tions)

OFF: No fatal error
ON: Fatal error

12 to 14

Reserved

15

Program status for this Motion Control Module

OFF: Stopped (PROGRAM mode)
ON: Executing (RUN or MONITOR mode)

CIO 0106

00 to 15

General-purpose refresh data from MM to CM

CIO 0107

00 to 15

CIO 0108

00 to 15

CIO 0109

00 to 15

Word

address

Bits

Details

Direc-

tion

Motion Control Module

allocation

Coordinator Module allocation

Word

address

Bits

Details

#1

#2

#3

#4

Word

address

Bit

Word

address

Bit

Word

address

Bit

Word

address

Bit

CM to
MM

CIO 0100 00 to 15 General-pur-

pose refresh
data from CM
to MM

CIO 0100 00 to 15 CIO 0110 00 to 15 CIO 0120 00 to 15 CIO 0130 00 to 15

CIO 0101 00 to 15

CIO 0101 00 to 15 CIO 0111 00 to 15 CIO 0121 00 to 15 CIO 0131 00 to 15

CIO 0102 00 to 15

CIO 0102 00 to 15 CIO 0112 00 to 15 CIO 0122 00 to 15 CIO 0132 00 to 15

CIO 0103 00 to 15

CIO 0103 00 to 15 CIO 0113 00 to 15 CIO 0123 00 to 15 CIO 0133 00 to 15

CIO 0104 00 to 15

CIO 0104 00 to 15 CIO 0114 00 to 15 CIO 0124 00 to 15 CIO 0134 00 to 15

MM to
CM

CIO 0105 00 to 07 Reserved

CIO 0105 00 to 07 CIO 0115 00 to 07 CIO 0125 00 to 07 CIO 0135 00 to 07

08

Reserved

08

08

08

08

09

Cycle time
over warning

09

09

09

09

10

Non-fatal
error

10

10

10

10

11

Fatal error

11

11

11

11

12 to 14 Reserved

12 to 14

12 to 14

12 to 14

12 to 14

15

Program sta-
tus

15

15

15

15

CIO 0106 00 to 15 General-pur-

pose refresh
data from
MM to CM

CIO 0106 00 to 15 CIO 0116 00 to 15 CIO 0126 00 to 15 CIO 0136 00 to 15

CIO 0107 00 to 15

CIO 0107 00 to 15 CIO 0117 00 to 15 CIO 0127 00 to 15 CIO 0137 00 to 15

CIO 0108 00 to 15

CIO 0108 00 to 15 CIO 0118 00 to 15 CIO 0128 00 to 15 CIO 0138 00 to 15

CIO 0109 00 to 15

CIO 0109 00 to 15 CIO 0119 00 to 15 CIO 0129 00 to 15 CIO 0139 00 to 15

Advertising