7-9 related areas, Related areas, System setup – Omron HOME SECURITY SYSTEM - MOTION SENSOR FQM1-MMA21 User Manual

Page 227

Advertising
background image

204

Functions for Servo Drivers Compatible with Absolute Encoders

Section 7-7

7-7-9

Related Areas

System Setup

Tab page

Function

Details

Time when

setting

becomes

effective

Pulse
Input

Counter 1

Pulse input
mode

0 hex: Phase differential x1
1 hex: Phase differential x2
2 hex: Phase differential x4
3 hex: Increment/decrement pulse input
4 hex: Pulse + direction

At power ON

Counter reset
method

0 hex: Software reset
1 hex: Phase Z and software reset

Counting Speed

0 hex: 50 kHz
1 hex: 500 kHz

Counter opera-
tion

0 hex: Linear counter
1 hex: Circular counter
2 hex: Absolute linear (CW

−)

3 hex: Absolute circular
4 hex: Absolute linear (CW+)

Counter data dis-
play

0 hex: Do not monitor
1 hex: Counter movements (mode 1)
2 hex: Frequency measurement (mode 2)

Note Frequency measurement can be set for

counter 1 only.

Sampling time
(for mode 1)

Sets the sampling time when the high-speed counter
PV is being measured (mode 1).

0000 hex: Cycle time
0001 to 270F hex: 1 to 9,999 ms (1-ms units)

Note This setting is used only when the Counter

Data Display parameter is set to 1 hex (mode
1).

Counter 2

Pulse input
mode

The counter 2 parameters have the same functions
as the parameters for counter 1, above.

Note The Counter Data Display parameter cannot

be set to frequency measurement (2 hex).

Counter reset
method

Counting Speed

Counter opera-
tion

Counter data dis-
play

Sampling time
(for mode 1)

Advertising