Serial Communications

Section 6-1

Note

When the Serial Gateway function is used, the FQM1 receives FINS com-
mands (encapsulated W-series or SMARTSTEP commands) via the RS-422A
port from NT-series PTs or personal computers and converts them to W-
series or SMARTSTEP Servo Driver commands (removes the encapsulation)
and transfers them to the W-series or SMARTSTEP Servo Drivers.

System Setup

Note

The settings are made using CX-Programmer Ver. 5.0

@ menus.

Smart Active Parts
Communications Settings

When using NS-series Smart Active Parts for Servo Drivers with the FQM1,
set the Destination Unit No. (U) to 251 on the Smart Active Parts Communica-
tions Settings Screen. No. 251 indicates the RS-422A port for the FQM1.

FQM1

Smart Active Parts

RS-422A

NS-series PT

NT Link

Coordinator Module

Protocol
conversion

Servo parameters or
other data

W-series or
SMARTSTEP
Servo Driver

W-series or
SMARTSTEP
Servo Driver

Item

Settings

Default

Enabled

Drive Tab Page

Mode

Serial Gateway or Non-procedural
(no-protocol)

Serial Gateway

Each cycle

RS-422 Response Time-
out of Command

0.1 to 25.5 s (unit: 0.1 s)

5 s