Functions for Servo Drivers Compatible with Absolute Encoders

Section 7-7

A606
and
A607

00 to 15 High-speed

Counter 2

Counter
operation

• Absolute

linear
(CW

−)

• Absolute

circular

• Absolute

linear
(CW+)

Absolute
No. of
rotations
PV

The same as for high-speed counter 1, except
that the high-speed counter frequency mea-
surement cannot be performed.

Motion Con-
trol Module

A608

04

High-speed
Counter 1
Status

Absolute No. of Rota-
tions Read Error Flag

OFF: No error
ON: Error occurred

Motion Con-
trol Module

05

Absolute No. of Rota-
tions Read Completed
Flag

OFF: Not reading or reading

ON: Reading completed (This is set at the

completion of receiving serial data on No.
of rotations.)

12

Absolute Offset Preset
Error Flag

An error occurred when storing the absolute
offset in the System Setup parameter area.

A609

04

High-speed
Counter 2
Status

Absolute No. of rota-
tions read error

These flags have the same functions as the
ones for High-speed Counter 1 Status, above.

Motion Con-
trol Module

05

Absolute No. of rota-
tions read completed

12

Absolute offset preset
error

A610

05

High-speed
Counter 1
Command

Absolute offset preset

OFF:

No preset

OFF to ON: Offset obtained from multi-turn

data from Servo Driver and the
No. of initial incremental pulses
are stored as the absolute offset.
When defining machine origin, dif-
ference between machine and
encoder's origins is preset as the
absolute offset.

Motion Con-
trol Module

06

Absolute PV preset

OFF:

Absolute PV preset invalid

OFF to ON: At this point, the absolute PV is

stored in high-speed counter PV 1
(A600 and A601).

Note Refer to 7-7-6 Absolute Present Value

for details on the absolute PV.

07

Absolute No. of rota-
tions read

OFF:

No. of rotations data read from

Servo Driver invalid

ON:

At the rising edge of the signal,

SEN is output to Servo Driver, and
multi-turn data is received from
the phase A input.

A611

05

High-speed
Counter 2
Command

Absolute Offset Preset

These control bits have the same functions as
the ones for High-speed Counter 1 Command,
above.

Motion Con-
trol Module

06

Absolute PV Preset

07

Absolute No. of Rota-
tions Read

Word

Bits

Function

Details

Controlled

by

Advertising