Omron HOME SECURITY SYSTEM - MOTION SENSOR FQM1-MMA21 User Manual

Page 188

Advertising
background image

165

Pulse Inputs

Section 7-5

Range

High-speed
Counter PV

Time

Content of A612

3

10000

Range

2

7500

Range

1

2500

A612: 0001 hex

0002 hex 0004 hex 0008 hex

0001 hex

0002 hex

0004 hex

0008 hex

0001 hex

PV reset on
phase-Z signal

PV reset on
phase-Z signal

15 14 13 12 11 10 9

8

6

5

4

3

2

7

1

0

0

0

0

0

0

0

0

0

0

0

0

1

0

0

0

0

0

0

0

0

0

0

1

0

0

0

0

0

0

0

0

0

1

0

0

0

Internal bit pattern

(0001 hex)

Content is transferred to CIO 0001
to turn ON CIO 0001.00.

(0002 hex)

Content is transferred to CIO 0001
to turn ON CIO 0001.01.

(0004 hex)

Content is transferred to CIO 0001
to turn ON CIO 0001.02.

0

0

0

0

0

0

0

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

(0008 hex)

Content is transferred to CIO 0001
to turn ON CIO 0001.03.

0

CTBL

#0001
#0001

D00000

Continually compares the high-speed counter PV
from high-speed counter 1 with the specified
ranges.(In this case, the comparison table
begins at D00000.)

D00000 0 0 0 4
D00001 0 0 0 0
D00002 0 0 0 0
D00003 2 5 0 0
D00004 0 0 0 0
D00005 0 0 0 1
D00006 2 5 0 1
D00007 0 0 0 0
D00008 7 5 0 0
D00009 0 0 0 0
D00010 0 0 0 2
D00011 7 5 0 1
D00012 0 0 0 0
D00013 0 0 0 0
D00014 0 0 0 1
D00015 0 0 0 4
D00016 0 0 0 1
D00017 0 0 0 1
D00018 F F F F
D00019 7 F F F
D00020 0 0 0 8

A610.00

Turns ON the High-speed Counter 1 Reset Bit.

P_On

(Always ON)

Reset Bit

A610.01

Starts high-speed counter 1.

Start high-speed

counter.

P_On

(Always ON)

END

MOV

A613

0001

Transfers the internal bit pattern from A613 to
CIO 0001.

4 comparison conditions

Lower limit

A 0

Upper limit

A 2500

Range

A

Bit pattern

Lower limit

B 2501

Upper limit

B 7500

Range

B

Bit pattern

Lower limit

C 7501

Upper limit

C 10000

Range

C

Bit pattern

Lower limit

D 10001

Upper limit

D 7FFFFFFF

Range

D

Bit pattern

Advertising