45

Module Current Consumption

Section 2-6

XW2B-80J7-1A Servo Relay Unit

2-6

Module Current Consumption

The amount of current/power that can be supplied to the Modules mounted in
the FQM1 is limited. Refer to the following tables when designing your system
so that the total current consumption of the mounted Modules does not
exceed the maximum current for each voltage system and the total power
consumption does not exceed the maximum for the Power Supply Unit.

Maximum Current and
Maximum Total Power
Consumption

The following table shows the maximum currents and power that can be sup-
plied by Power Supply Units to the Controller.

Current Consumption for Each Module

Current Consumption for 5-V System

Note

The current consumption increases by 0.15 A/Module if NT-AL001 Link Adapt-
ers are used.

160

4.5 dia.

Phase B switches

Signal switches

Terminating resistance switch

100 90

41.7

15.9

30.7

Power Supply

Unit

Max. current consumption

Max. total

power con-

sumption

5-V system

(internal logic)

24-V system

(analog)

24-V system

(service)

CJ1W-PA202

2.8 A

0.4 A

None

14 W

CJ1W-PA205R

5.0 A

0.8 A

None

25 W

Name

Model

5-V system current

consumption (A)

Coordinator Module

Note The listed value includes the

current consumption for the
CX-Programmer.

FQM1-CM001

0.47 (See note.)

End Module

FQM1-TER01

Included in Coordinator
Module current consumption