345

System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations

Appendix C

FAL/FALS Errors

Memory Errors

System Setup

I/O Errors

Module Errors

A500

14

Error Log Pointer Reset
and Memory Not Held
Flag OFF Bit

The error log pointer in A408 is reset to 0000 hex and Memory Not
Held Flag (A404.14) is turned OFF when this bit is turned ON.

User

A400

00 to 15 Error code

When a non-fatal error (user-defined FAL(006) or system error) or a
fatal error (user-defined FALS(007) or system error) occurs, the hexa-
decimal error code is written to this word.

Module

Address

Bits

Name

Function

Controlled by

A401

06

FALS Error Flag
(fatal error)

Turns ON when a non-fatal error is generated by the FALS(006)
instruction. The FQM1 will stop operating.

Module

A402

15

FAL Error Flag
(non-fatal error)

Turns ON when a non-fatal error is generated by executing FAL(006).
The FQM1 will continue operating.

Address

Bits

Name

Function

Controlled by

A401

15

Memory Error Flag (fatal
error)

Turns ON when there is an error in the memory. FQM1 operation will
stop and the ERR indicators on the front of the Modules will light.

Module

A403

00

UM Error Flag

Turns ON when there is an error in the user memory.

04

System Setup Error
Flag

Turns ON when there is an error in the System Setup in the Coordina-
tor Module or Motion Control Module.

10

Flash Memory Error
Flag

Turns ON when the flash memory is physically destroyed.

13

Analog Offset/Gain
Error Flag

Turns ON when there is an error in the analog I/O offset/gain adjust-
ment value in flash memory.

14

Flash Memory DM
Checksum Error Flag

Turns ON when there is an error in the DM Area data backed up in
flash memory in the Coordinator Module.

A404

14

Memory Not Held Flag

Turns ON when corruption is found in the check performed after turn-
ing ON power in the areas backed up during power interruptions (DM
Area (Coordinator Module only) and Error Log Area).

Address

Bits

Name

Function

Controlled by

A402

10

System Setup Error
Flag

Turns ON when there is a setting error in the System Setup.

Module

A409

00 to 15 System Setup Error

Location

When there is a setting error in the System Setup, the location of that
error is written to A409 in 4-digit hexadecimal.

Address

Bits

Name

Function

Controlled by

A401

10

I/O Setting Error Flag

Turns ON when more than four Motion Control Modules are connected
to the Coordinator Module.

Module

Address

Bits

Name

Function

Controlled by

A402

05

Motion Control Module
Monitoring Error Flag
(Coordinator Module
only)

Turns ON in the Coordinator Module when a system error, such as a
WDT error, occurs in any of the Motion Control Modules.

Module

13

Coordinator Module
WDT Error Flag (Motion
Control Modules only)

Turns ON in the Motion Control Modules when a WDT error occurs in
the Coordinator Module.

14

Coordinator Module
Fatal Error Flag (Motion
Control Modules only)

Turns ON in the Motion Control Modules when a fatal error occurs in
the Coordinator Module.

Address

Bits

Name

Function

Controlled by