Rockwell Automation 1336T FORCE Series B User Manual

Page 102

Advertising
background image

Chapter 4

Startup

4–11

AB0270A

or

Drive Data
Startup

Linear List
Startup

After the feedback device type has been selected
and accepted, press the ESC key to return to the
Startup Menu. The display should appear as
shown below:

STARTUP MENU:

Use the INC/DEC keys to scroll thru the Startup
Mode menu selections until DRIVE DATA
is reached.

Press the ENTER key to access the Drive Data
menu.

NOTE: These parameters
are primarily motor/
encoder specific param-
eters that are used for
scaling Drive output to
motor input require-
ments.

DRIVE DATA
DRIVE TUNE

LIMITS

FAULT SETUP

MONITOR

LINEAR LIST

DRIVE DATA MENU:

Not Used in

Sensorless Mode

The HIM will allow you to toggle between the I/O
Drive Data menu parameters using the INC/DEC
keys. The definitions of the I/O Drive Data menu
parameters is detailed below:

Language Select – This parameter indicates
whether English or an alternate language will
be used for parameter and fault display text.

Input Mode – Defines the function of the inputs
on the “L” option board

Encoder PPR – Number of pulses per revolution
for encoder.

Base Motor Speed – Motor Nameplate Speed

Base Motor HP – Motor Nameplate Horsepower

Base Motor Current – Motor Nameplate Current

Base Motor Volts – Motor Nameplate Voltage

Base Motor Frequency – Motor Nameplate
Frequency

Language Select #304

Input Mode #385

Encoder PPR #235

Base Motor Speed #229

Base Motor HP #228

Base Motor Current #280

Base Motor Volts #231

Base Motor Freq #232
Torq Mode Select #53

Undervoltage Setpoint

#224*

Motor Poles #235

NOTE: It is important that you retain a record of the
feedback device that was selected, because the
bandwidth of the velocity regulator will be
significantly reduced when the drive is used without
an encoder.

*If using a 230V drive,
parameter 224 should be
set to a value of 200V.