Rockwell Automation 1336T FORCE Series B User Manual

Page 56

Advertising
background image

Chapter 2
Installation/Wiring

2–36

Figure 2.23 provides the terminal designations for TB3. The maximum and
minimum wire size accepted by TB3 is 2.1 and 0.30 mm

2

(14 and 22

AWG). Maximum torque for all terminals is 1.36 N–m (12 lb.–in.). Use
Copper wire only.

Figure 2.23.
TB3 Terminal Designations

NOTE: Terminals 31 thru 36 are not used with 1336 FORCE applications

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

Included on L4E, L5E & L6E Only

NOT USED

Input 1

Input 2 (Stop)

Common

Input 3

Input 4

Input 5

Common

Input 6

Input 7

Input 8

Common

Enable

Encoder B

Encoder NOT

A

Encoder NOT

B

Encoder A

+12V (200mA

max.)

Encoder Common

The following table defines the input state of the Speed Select inputs for a
desired frequency source.

Table 2.E
Speed Select Input State vs. Frequency Source

Speed Select 3

Speed Select 2

Speed Select 1

Velocity Reference Source

TB3

Terminal 26

Terminal 27

Terminal 28

Interface Option (MOD L4,L5,L6)

O

O

O

Ext Ref 1 Para 101*

O

O

X

Preset Speed Ref 1 (P 119)

O

X

O

Preset Speed Ref 2, (P 120)

O

X

X

Preset Speed Ref 3, (P 121)

X

O

O

Preset Speed Ref 4, (P 122)

X

O

X

Preset Speed Ref 5, (P 123)

X

X

O

External Reference 2 (P 104)

X

X

X

Last State

Equivalent truth table implemented in Parameter 52 Logic Command Word

Para 52

Bit 14

Bit 13

Bit 12

Velocity Reference Source Bits

O

O

X

Ext Ref 1 (P 101)

O

X

O

Preset Speed Ref 1 (P 119)

O

X

X

Preset Speed Ref 2 (P 120)

X

O

O

Preset Speed Ref 3 (P 121)

X

O

X

Preset Speed Ref 4 (P 122)

X

X

O

Preset Speed Ref 5 (P 123)

X

X

X

External Reference 2 (P 104)

O

O

O

No Reference or Last State

0 = Open – input removed, X = Closed – input present