Rockwell Automation 1336T FORCE Series B User Manual

Page 209

Advertising
background image

Chapter 5
Programming Parameters

5–83

MOP Value
[Mop Value]

Parameter Number

394

Parameter Type

Source

Display Units

x RPM

Drive Units

4096 = Base Speed

Factory Default

0.0

Minimum Value

Negative Speed Limit

Maximum Value

Positive Speed Limit

This parameter displays the MOP value.

I/O Deceleration Rate 2
[Decel Rate 2]

Parameter Number

392

Parameter Type

Sink

Display Units

x.x sec

Drive Units

10 = 1 sec

Factory Default

10.0 sec

Minimum Value

0.0 sec

Maximum Value

6553.5 sec

This parameter determines the base speed
to 0 rpm ramp rate.

Mop Increment
[Mop Increment]

Parameter Number

393

Parameter Type

Sink

Display Units

x.x RPM (RPM per sec)

Drive Units

4096= Base Speed

Factory Default

10% of base speed

Minimum Value

0.0 RPM

Maximum Value

Base Speed

This parameter determines the rate of
increase or decrease to the MOP value
per time.

I/O Deceleration Rate 1
[Decel Rate 1]

Parameter Number

391

Parameter Type

Sink

Display Units

x.x sec.

Drive Units

10 = 1 sec

Factory Default

10.0 sec

Minimum Value

0.0 sec

Maximum Value

6553.5 sec

This parameter determines the base speed
to 0 rpm ramp rate.

I/O Acceleration Rate 2
[Accel Rate 2]

Parameter Number

390

Parameter Type

Sink

Display Units

x.x sec

Drive Units

10 = 1 sec

Factory Default

10.0 sec

Minimum Value

0.0 sec

Maximum Value

6553.5 sec

This parameter determines the 0 rpm to
base speed ramp rate.

I/O Stop Select 2
[Stop Select 2]

Parameter Number

388

Parameter Type

Sink

Display Units

x

Drive Units

None

Factory Default

0

Minimum Value

0

Maximum Value

3

This parameter selects the stopping mode
for a valid stop command.
3 = Param 59 Bits 4 or 5
2 = Current limit stop
1 = Ramp Stop
0 = Coast Stop

I/O Acceleration Rate 1
[Accel Rate 1]

This parameter determines the 0 rpm to
base speed ramp rate.

Parameter Number

389

Parameter Type

Sink

Display Units

x.x Sec

Drive Units

10 = 1 sec

Factory Default

10 sec

Minimum Value

0.0 sec

Maximum Value

6553.5 sec

Advertising