5–61

Encoder PPR
[Encoder PPR]

Parameter Number

235

Parameter Type

Sink

Display Units

x PPR

Drive Units

None

Factory Default

1,024 ppr

Minimum Value

500 ppr

Maximum Value

20,000 ppr

User entered pulse per revolution rating of
the feedback device when using an
encoder to determine motor velocity.

RS Tune
[Stator Res]

Parameter Number

236

Parameter Type

Sink

Display Units

x.xx %

Drive Units

4096 = 100.00% Stator Res

Factory Default

1.50%

Minimum Value

0.00%

Maximum Value

100.00%

Lsigma Tune [Leakage Inductance]
[Leakage Ind]

Parameter Number

237

Parameter Type

Sink

Display Units

x.xx%

Drive Units

4096 = 100% Leakage Ind.

Factory Default

18.00%

Minimum Value

0.00%

Maximum Value

100.00%

Id Tune [Base Flux Current]
[Base Flux Cur]

Parameter Number

238

Parameter Type

Sink

Display Units

x.x%

Drive Units

4096 = 100.0% motor amps

Factory Default

30.0%

Minimum Value

0.0%

Maximum Value

75.0%

Sum of the stator and cable resistances of
the motor in a per unit (percent representa-
tion) This parameter is determined by the
autocommissioning routine.

Sum of the motor stator and rotor leakage
inductances and the motor cable induc-
tance in a per unit base impedance. This
parameter is determined by the autocom-
missioning routine.

Magnetizing current which produces rated
flux in the motor in a per unit (percent)
representation. This parameter is deter-
mined by the autocommissioning routine
but can be entered manually.

Iq Tune (Rated Torque Current)
[Base Torque Cur]

Parameter Number

240

Parameter Type

Sink

Display Units

x.xx%

Drive Units

1024 = 100.00% Iq Motor

Factory Default

95.40 %

Minimum Value

0.00%

Maximum Value

100.00%

Current which produces rated torque in the
motor in a per unit (percent) representa-
tion. This parameter is determined by the
autocommissioning routine but can be en-
tered manually.

Vde Tune (Base Torque Voltage)
[Base Torque Volt]

Parameter Number

241

Parameter Type

Sink

Display Units

x.x volts

Drive Units

16 = 1 volt (L–N)

Factory Default

–75.0 volts

Minimum Value

–468.0 volts

Maximum Value

0.0 volts

D axis voltage command to the motor at
rated speed and rated current. Parameter
calculated by autocommissioning routine
and MUST NOT BE CHANGED. Data
represented as X.X volts

Vde Maximum (Peak HP)
[Vde Max]

Parameter Number

243

Parameter Type

Sink

Display Units

x.x volts

Drive Units

16 = 1 volt line to neutral peak

Factory Default

112.5 volts

Minimum Value

0.0 volts

Maximum Value

468.0 volts

Maximum D axis voltage allowed on the
motor. Parameter calculated by autocom-
missioning routine and MUST NOT BE
CHANGED. Data represented as X.X
volts.

Vqe Tune (Rated Flux Voltage)
[Base Flux Volt]

Parameter Number

242

Parameter Type

Sink

Display Units

x.x volts

Drive Units

16 = 1 volt (L–N)

Factory Default

367.0 volts

Minimum Value

0.0 volts

Maximum Value

468.0 volts

Q axis voltage command to the motor at
rated speed and rated current if motor is
not in field weakening. Parameter calcu-
lated by autocommissioning routine and
MUST NOT BE CHANGED. Data repre-
sented as X.X volts.

Advertising