Chapter 5
Programming Parameters

5–44

CP Warning/None Configuration Select
[CP Warn Select]

Parameter Number

87

Parameter Type

Sink

Display Units

Bits

Drive Units

None

Factory Default

0000 0000 0001 1111

Minimum Value

0000 0000 0000 0000

Maximum Value

1111 1111 1111 1111

Enums:

This word parameter determines conditions
detected by the Current Processor (CP)
that will be reported as either a drive fault
or drive warning condition. Each configu-
ration bit matches the bit definition of Pa-
rameter 82, 84 and 86. When a bit is set to
“1”, the corresponding condition in the
Drive will be reported as a FAULT, other-
wise the condition is reported as a
WARNING.

VP Fault/Warning Configuration Select
[VP Fault Select]

Parameter Number

88

Parameter Type

Sink

Display Units

Bits

Drive Units

None

Factory Default

1111 1111 1111 1111

Minimum Value

0000 0000 0000 0000

Maximum Value

1111 1111 1111 1111

Enums:

This word parameter determines conditions
detected by the Velocity Processor (VP)
that will be reported as either a drive
FAULT or drive WARNING condition. Each
configuration bit matches the bit definitions
of Parameters 83, 85 and 89. When a bit
is set to “1” the corresponding condition in
the Drive will be reported as a FAULT,
otherwise the condition is reported as a
WARNING.

Bit

Condition

0

Bus Ridethrough Timeout

1

Bus Precharge Timeout

2

Bus Drop (150 volts)

3

Bus Undervoltage

4

Bus Drop Cycles

5

Fast Flux Up Current < 50%

Bit

Condition

0

Encoder Feedback Loss

1

Inverter Overemp Pending

2

Motor Overtemperature Tripped

3

Motor Overload Pending (I

2

T)

4

Motor Overload Trip (I

2

T)

5

Motor Stalled

6

External Fault

7

RMS Fault

8

Reserved, Leave Zero

Bit

Condition

9

Parameter Limit

10

Math Limit

11

Dynamic brake overtemp

12

AC Motor Contactor Failure

13

Inverter Overload Pending (IT)

14

Drive to Drive Fault

15

Inverter Overload Trip (IT)

VP Warning/None Configuration Select
[VP Warn Select]

Parameter Number

89

Parameter Type

Sink

Display Units

Bits

Drive Units

None

Factory Default

1111 1111 1111 1111

Minimum Value

0000 0000 0000 0000

Maximum Value

1111 1111 1111 1111

Enum:

This parameter determines conditions de-
tected by the Velocity Processor (VP) that
will be reported as either a drive FAULT or
WARNING or not reported (ignored). Each
configuration bit matches the bit definitions
of Parameters 83, 85 and 88. When a bit
is set to “1”, the corresponding condition in
the Drive will be reported as configured by
parameter 88. If the bit is set to “0”, the
condition is not reported.

Bit

Condition

0

Encoder Feedback Loss

1

Inverter Overtemp Pending

2

Motor Overtemperature Tripped

3

Motor Overload Pending (I

2

T)

4

Motor Overload Trip (I

2

T)

5

Motor Stalled

6

External Fault

7

RMS Fault

Bit

Condition

8

Not Used

9

Parameter Limit

10

Math Limit

11

Dynamic brake overtemp

12

AC Motor Contactor Failure

13

Inverter Overload Pending (IT)

14

Drive to Drive Fault

15

Inverter Overload Foldback (IT)