Rockwell Automation 1336T FORCE Series B User Manual

Page 163

Advertising
background image

Chapter 5
Programming Parameters

5–37

Auto Tune Testpoint Select
[Auto Tune TP Sel]

This parameter selects what internal loca-
tion of the Velocity Auto Tune Controller
will become the testpoint value shown in
P47. The internal locations available are:

Select Value

Autotune Access Point

Parameter Number

48

Parameter Type

Sink

Display Units

None

Drive Units

None

Factory Default

0

Minimum Value

0

Maximum Value

10

Enums:

0
1
2
3
4

Zero
Autotune Status Bits
Autotune Inhibit Word (all zero = OK)
Autotune Error Word (all zero = OK)
Calculated Friction (4096 @ 1 pu)

Torque Limit for autotune
Autotune State Word 1
Autotune State Word 2
Autotune Control Bits
Minimum Limit for di/dt to acheive requested bandwidth
Minimum error filter bandwidth

Select Value

Autotune Access Point

5
6
7
8
9
10

Logic Command Word
[Logic Command]

Parameter Number

52

Parameter Type

Source

Display Units

Bits

Drive Units

None

Factory Default

0000 0000 0000 0000

Minimum Value

0000 0000 0000 0000

Maximum Value

1111 1111 1111 1111

This word parameter contains data used to
Control Drive logic operation. If a bit is set
the function is enabled, otherwise it is
disabled (inactive).

C

B A

0
0
0
0
1
1
1
1

0
0
1
1
0
0
1
1

0
1
0
1
0
1
0
1

Zero
– External Ref
– Preset Speed 1
– Preset Speed 2
– Preset Speed 3
– Preset Speed 4
– Preset Speed 5
– External Ref. 2

BITS

0
1
2
3
4
5
6
7
8
9

10
11
12
13
14
15

Ramp Stop
– Start
– Jog 1
– Clear Fault
– Forward
– Reverse
– Jog 2
– Current Limit Stop
– Coast Stop
– Ramp Disable
– Flux Enable
– Process Trim Enable
– Velocity Ref Select A
– Velocity Ref Select B
– Velocity Ref Select C
– Reset Drive

Torque Mode Select
[Torque Mode Sel]

This is a word parameter used to select the
source for the drive torque reference. The
operation of this parameter functions as a
selector switch. The position of the
selector determines the torque reference
selection as follows:

Value

Description

0

Zero Torque

1

Velocity Regulate

2

External Torque

Parameter Number

53

Parameter Type

Sink

Display Units

x

Drive Units

None

Factory Default

1

Minimum Value

0

Maximum Value

5

Value

Description

3

Min Select Speed/Torque (Selects the smallest value when the torque
reference and the torque generated from the speed are compared.)

4

Max Select Speed/Torque (Selects the largest value when the torque
reference and the torque generated from the speed are compared.

5

Sum Speed and Torque (selects the sum of the torque reference and the
torque generated from the speed.)

Advertising