Rockwell Automation 1336T FORCE Series B User Manual

Page 210

Advertising
background image

Chapter 5
Programming Parameters

5–84

Pulse Value
[Pulse Value]

Parameter Number

399

Parameter Type

Source

Display Units

x.x RPM

Drive Units

4096 = Pulse Scale

Factory Default

0.0

Minimum Value

–8 x Pulse Scale

Maximum Value

+8 x Pulse Scale

This parameter displays the pulse input
value.

Pulse Offset
[Pulse Offset]

Parameter Number

398

Parameter Type

Sink

Display Units

x.x RPM

Drive Units

None

Factory Default

0.0

Minimum Value

– Pulse Scale

Maximum Value

+ Pulse Scale

This parameter determines the minimum
speed the pulse input will go to.

This parameter determines the pulse input
speed that is equal to 4096 drive units.

Pulse Scale
[Pulse Scale]

Parameter Number

397

Parameter Type

Sink

Display Units

x RPM

Drive Units

4096

Factory Default

1750

Minimum Value

–6000

Maximum Value

+6000

SP Comm Retries
[SP Comm Retries]

Parameter Number

404

Parameter Type

Source

Display Units

x.

Drive Units
Factory Default

0.0

Minimum Value

0

Maximum Value

65535

This parameter monitors the amount of
SCANport communications errors
that have occurred since power up.

Pulse PPR
[Pulse PPR]

Parameter Number

395

Parameter Type

Sink

Display Units

x PPR

Drive Units

None

Factory Default

1024

Minimum Value

500

Maximum Value

20000

This parameter determines the pulse input
pulses per revolution.

Pulse Single or Double Edge
[Pulse Edge]

Parameter Number

396

Parameter Type

Sink

Display Units

None

Drive Units

None

Factory Default

1

Minimum Value

1

Maximum Value

2

Enums:
1 = 1 Edge
2 = 2 Edges

This parameter determines if rising (single)
or rising and falling (double) edges are
counted for the pulse input.

Advertising