Chapter 5
Programming Parameters

5–31

Drive Software Version
[Drive SIO Version]

Parameter Number

01

Parameter Type

Source

Display Units

x.xx

Drive Units

Display units x 100

Factory Default

1.01

Minimum Value

0.00

Maximum Value

9.99

Power Structure Type
[Drive Type]

Parameter Number

05

Parameter Type

Source

Display Units

x

Drive Units

None

Factory Default

0

Minimum Value

0

Maximum Value

65635

This parameter stores the present software
revision for the firmware product.
The firmware value represents the soft-
ware version in the range 00.0 to 99.9.

This number is a unique code that identi-
fies the drive’s current and voltage ratings.
This number originates from a serial EE
memory located on the Drive’s Base Drive
Board.

Motor Control Counter
[MCB Counter]

Parameter Number

08

Parameter Type

Source

Display Units

x.x sec

Drive Units

None

Factory Default

x 10 sec

Minimum Value

0.0 sec

Maximum Value

65535.5 sec

This parameter contains a counter that
increments by 1 every 0.1 seconds. It is
intended to be a monitor parameter to
indicate that the Motor Control Board
Velocity Processor firmware is executing.

Drive Link Task Interval
[D2D Tsk Interval]

Parameter Number

09

Parameter Type

Sink

Display Units

x ms

Drive Units

x/2

Factory Default

2

Minimum Value

1

Maximum Value

10

Drive Link Baud Rate
[D2D Baud Rate]

Parameter Number

10

Parameter Type

Sink

Display Units

Kbaud

Drive Units

None

Factory Default

0

Minimum Value

0

Maximum Value

2

Drive Link Transmit Address
[D2D Xmit Addr]

Parameter Number

11

Parameter Type

Sink

Display Units

x

Drive Units

None

Factory Default

0

Minimum Value

0

Maximum Value

64

This parameter specifies the interval at
which drive to drive data will be transmitted
and received. The intervals are 2 ms
intervals up to 20 ms.

1 = 2 ms scan
2 = 4 ms scan

5 = 10 ms scan

8 = 16 ms scan

3 = 6 ms scan

6 = 12 ms scan

9 = 18 ms scan

4 = 8 ms scan

7 = 14 ms scan

10 = 20 ms scan

This word parameter specifies the baud
rate used on the drive-to-drive link (CAN)
communication interface as follows:
00H = 125K baud
01H = 250K baud
02H = 500K baud

This parameter specifies the node address
at which two words of data will be trans-
mitted. A value of zero disables the trans-
mit function.

Drive Link Receive 1 Address
[D2D Rcv 1 Addr]

Parameter Number

12

Parameter Type

Sink

Display Units

x

Drive Units

None

Factory Default

0

Minimum Value

0

Maximum Value

64

This parameter specifies the node address
at which two words of data will be
received. A value of zero disables the
receive function.

Refer to Document Update