Appendix

C

C–1

User Parameter Values

Use the tables on the following pages to record your particular parameter
value setting for the current application.

No.

Name

Default

Value

No.

Name

Default

Value

1

Drive Software Ver

1.01

47

Autotune TP Data

0000 0000 0000 0000

5

Power Struct Type

0

48

Autotune TP Select

0

8

Motor Cntrl Counter

0.0 sec

52

Logic Cmd Word

0000 0000 0000 0000

9

Drv Comm Tsk Intrvl

1

53

Torque Mode Sel

1

10

Drv Comm Baud Rate

0

54

Local Input Status

0000 0000 0000 0000

11

Drv Comm Trans Addr

0

55

Local Output Status

0000 0000 0000 0000

12

Drv Comm Rcv 1 Addr

0

56

Logic Status Low

0000 0000 0000 0000

13

Drv Comm Rcv 2 Addr

0

57

Logic Status Hi

0000 0000 0000 0000

14

Dr Comm Xmit Ind 1

20

58

Torq Stop Config

0

15

Dr Comm Xmit Ind 2

21

59

Logic Options

0000 0001 1000 0010

16

Dr Comm Rcv 1 Ind 1

22

60

At Setpoint 1

+0.0%

17

Dr Comm Rcv 1 Ind 2

23

61

At Setpoint 2

+0.0%

18

Dr Comm Rcv 2 Ind 1

24

62

Over Setpoint 1

+0.0%

19

Dr Comm Rcv 2 Ind 2

25

63

Over Setpoint 2

+0.0%

20

Dr Comm Xmit Data 1

0

64

Over Setpoint 3

+0.0%

21

Dr Comm Xmit Data 2

0

65

Over Setpoint 4

+0.0%

22

Dr Comm Rcv1, Data 1

0

66

Setpoint Select

0000 0000 0000 0000

23

Dr Comm Rcv1, Data 2

0

67

Spd Setpoint Tol

base speed/100

24

Dr Comm Rcv2, Data 1

0

68

Cur Setpoint Tol

2.0%

25

Dr Comm Rcv2, Data 2

0

69

Zero Spd Tolerance

base speed/100

26

Process Trim Output

+0.00%

70

Logic Testpoint Data

0000 0000 0000 0000

27

Process Trim Ref

+0.00%

71

Logic Testpoint Sel

0

28

Process Trim Fdbk

+0.00%

72

Stop Dwell

1.0 sec.

29

Process Trim Select

0000 0000 0000 0000

77

Max Dyn Brake Pwr

0 Watts

30

Proc Trim Fltr Bdwth

0 radian/seconds

78

Max Dyn Brake Tmp

50 deg

31

Proc Trim Data

+0.0%

79

Dyn Brk Time Const

10 sec.

32

Proc Trim KI Gain

1.000

80

Pwr Up Diag Flt Sts

0000 0000 0000 0000

33

Proc Trim KP Gain

1.000

81

Non Config Flt Sts

0000 0000 0000 0000

34

Proc Trim Lo Lmt

–100.0%

82

CP Config Flt Sts

0000 0000 0000 0000

35

Proc Trim Hi Lmt

–100.0%

83

VP Config Flt Sts

0000 0000 0000 0000

36

Proc Trim Out Gain

+1.00

84

CP Config Warn Sts

0000 0000 0000 0000

37

Process Trim Tstpnt

+0

85

VP Config Warn Sts

0000 0000 0000 0000

38

Proc Trim TP Sel

0

86

CP Flt/Warn Sel

0000 0000 0000 0000

40

Auto Tune Trq Lmt

50.0%

87

CP Warn Config Sel

0000 0000 0000 0000

41

Auto Tune Speed

0.85 x Base Motor Spd

88

VP Fault Select

1111 1111 1111 1111

43

VP Desired BW

5.00 radian/seconds

89

VP Warn Config Sel

0000 0000 0000 0000

44

Autotune Status

50.00 radian seconds

90

Abslte Ovrspd Thrsh

0.1 x base speed

45

VP Damping Factor

1.0

91

Stall Delay

1.0 sec.

46

Total Inertia

20.0 sec.

92

Mtr Overload Limit

200.0%

Advertising