Rockwell Automation 1336T FORCE Series B User Manual

Page 199

Advertising
background image

Chapter 5
Programming Parameters

5–73

SCANport Start Mask
[Start Mask]

Parameter Number

332

Parameter Type

Sink

Display Units

Bits

Drive Units

None

Factory Default

0111 1111

Minimum Value

0000 0000

Maximum Value

0111 1111

Enums:

This parameter selects which SCANport
devices can issue a start command.
1 = Permit Control
0 = Deny Control

SCANport Jog Mask
[Jog Mask]

Parameter Number

333

Parameter Type

Sink

Display Units

Bits

Drive Units

None

Factory Default

0111 1111

Minimum Value

0000 0000

Maximum Value

0111 1111

Enums:

This parameter selects which SCANport
devices can issue a Jog command.
1 = Permit Control
0 = Deny Control

Bit 0 – TB3
Bit 1 – SCANport Device 1
Bit 2 – SCANport Device 2

Bit 3 – SCANport Device 3
Bit 4 – SCANport Device 4
Bit 5 – SCANport Device 5

Bit 6 – SCANport Device 6 (Int Gateway)
Bit 7 – Reserved

Bit 0 – TB3
Bit 1 – SCANport Device 1
Bit 2 – SCANport Device 2

Bit 3 – SCANport Device 3
Bit 4 – SCANport Device 4
Bit 5 – SCANport Device 5

Bit 6 – SCANport Device 6 (Int Gateway)
Bit 7 – Reserved

SCANport Clear Fault Mask
[Clear Fault Mask]

Parameter Number

335

Parameter Type

Sink

Display Units

Bits

Drive Units

None

Factory Default

0111 1111

Minimum Value

0000 0000

Maximum Value

0111 1111

Enums:

This parameter selects which SCANport
devices can issue a Clear Faults
command.
1 = Permit Control
0 = Deny Control

Bit 0 – TB3
Bit 1 – SCANport Device 1
Bit 2 – SCANport Device 2

Bit 3 – SCANport Device 3
Bit 4 – SCANport Device 4
Bit 5 – SCANport Device 5

Bit 6 – SCANport Device 6 (Int Gateway)
Bit 7 – Reserved

SCANport Reference Mask
[Reference Mask]

Parameter Number

334

Parameter Type

Sink

Display Units

Bits

Drive Units

None

Factory Default

0111 1111

Minimum Value

0000 0000

Maximum Value

0111 1111

Enums:

This parameter selects which SCANport
device can issue a reference command.
1 = Permit Control
0 = Deny Control

Bit 0 – TB3
Bit 1 – SCANport Device 1
Bit 2 – SCANport Device 2

Bit 3 – SCANport Device 3
Bit 4 – SCANport Device 4
Bit 5 – SCANport Device 5

Bit 6 – SCANport Device 6 (Int Gateway)
Bit 7 – Reserved

SCANport Direction Mask
[Direction Mask]

Parameter Number

331

Parameter Type

Sink

Display Units

Bits

Drive Units

None

Factory Default

0111 1111

Minimum Value

0000 0000

Maximum Value

0111 1111

Enums:

This parameter selects which SCANport
devices can issue a forward/reverse
command.
1 = Permit Control
0 = Deny Control

Bit 0 – TB3
Bit 1 – SCANport Device 1
Bit 2 – SCANport Device 2

Bit 3 – SCANport Device 3
Bit 4 – SCANport Device 4
Bit 5 – SCANport Device 5

Bit 6 – SCANport Device 6 (Int Gateway)
Bit 7 – Reserved