Rockwell Automation 1336T FORCE Series B User Manual

Page 164

Advertising
background image

Chapter 5
Programming Parameters

5–38

Local Input Status
[Local In Status]

Parameter Number

54

Parameter Type

Source

Display Units

Bits

Drive Units

Bits

Factory Default

0000 0000 0000 0000

Minimum Value

0000 0000 0000 0000

Maximum Value

1111 1111 1111 1111

Enums:

This parameter indicates boolean input sta-
tus conditions for the Velocity Processor.
When a bit is set to 1, the corresponding
input signal is true.

Local Output Status
[Local Out Status]

Parameter Number

55

Parameter Type

Source

Display Units

Bits

Drive Units

Bits

Factory Default

0000 0000 0000 0000

Minimum Value

0000 0000 0000 0000

Maximum Value

1111 1111 1111 1111

Enums:

This parameter indicates boolean output
status conditions for the Velocity Proces-
sor. When a bit is set to 1, the correspond-
ing input signal is true.

Value

Description

0

Brake Request

1

Drive Enable

2

Motor Overtemp Thermoguard

3

Discrete Stop

Value

Description

4

External Fault

5

RMS Fault

6

0 = Parall Inv

7

Single Lang

Value

Description

8

Test Diag

9

Inverter Status

10

Contactor Verify

11

Not Used

Value

Description

12

Not Used

13

Not Used

14

Not Used

15

Not Used

Value

Description

0

Brake Enable

1

Turn On Delay Select

2

Not Used

3

Not Used

Value

Description

4

Not Used

5

Not Used

6

Not Used

7

Not Used

Value

Description

8

Not Used

9

VP Enable

10

Pilot Relay

11

Not Used

Value

Description

12

VP Green LED

13

VP Red LED

14

Not Used

15

Not Used

Logic Status Low
[Logic Status Low]

Parameter Number

56

Parameter Type

Source

Display Units

Bits

Drive Units

Bits

Factory Default

0000 0000 0000 0000

Minimum Value

0000 0000 0000 0000

Maximum Value

1111 1111 1111 1111

This parameter is the Low part of a double
word that indicates boolean logic condi-
tions within the Drive. When a bit is set to
1, the corresponding condition in the Drive
is true.

Logic Status Hi
[Logic Status Hi]

Parameter Number

57

Parameter Type

Source

Display Units

Bits

Drive Units

None

Factory Default

0000 0000 0000 0000

Minimum Value

0000 0000 0000 0000

Maximum Value

1111 1111 11111 1111

Enums:

This parameter is the Hi part of a double
word that indicates boolean logic condi-
tions within the Drive. When a bit is set to
1, the corresponding condition in the Drive
is true.

Value

Description

0

Ready to Run

1

Drive Running

2

Cmd Direction (1=FWD, 0=Rev)

3

Rotation Direction

(1=FWD, 0=Rev)

Value

Description

4

Accelerating (1=Accel)

5

Decelerating (1=Decel)

6

Warning

7

Faulted

Value

Description

8

At Set Speed

9

Local A

10

Local B

11

Local C

Value

Description

12

At Zero Speed

13

Reference A

14

Reference B

15

Reference C

Value

Description

0

Flux Ready

1

Flux Up

2

Not Used

3

Not Used

Value

Description

4

Bus Ridethru

5

Jogging

6

Not Used

7

Not Used

Value

Description

8

At Limit

9

Not Used

10

At Setpoint 1

11

At Setpoint 2

Value

Description

12

Over Setpoint 1

13

Over Setpoint 2

14

Over Setpoint 3

15

Over Setpoint 4

C B A

0 0 0

No Change

0 0 1

Ref 1

0 1 0

Ref 2

0 1 1

Ref 3

1 0 0

Ref 4

1 0 1

Ref 5

1 1 0

Ref 6

1 1 1

Ref 7