Rockwell Automation 1336T FORCE Series B User Manual

Page 173

Advertising
background image

Chapter 5
Programming Parameters

5–47

Velocity Reference 2 LOW (Fraction)
[Vel Ref 2 Low]

Parameter Number

103

Parameter Type

Sink

Display Units

x

Drive Units

None

Factory Default

0

Minimum Value

0

Maximum Value

65535

Velocity Reference 2 HI (Whole 32 bit)
[Vel Ref 2 Hi]

Parameter Number

104

Parameter Type

Sink

Display Units

+/– x.x rpm

Drive Units

4096 = Base Motor Speed

Factory Default

+ 0.0 rpm

Minimum Value

– 8 x Base Speed

Maximum Value

+ 8 x Base Speed

Velocity Scale Factor 2
[Vel Scale Fctr 2]

Velocity Trim LOW
[Vel Trim Low]

Parameter Number

106

Parameter Type

Sink

Display Units

x Sec.

Drive Units

None

Factory Default

0

Minimum Value

0

Maximum Value

65535

Parameter Number

105

Parameter Type

Sink

Display Units

+/– x.xxxx

Drive Units

8192 = 1.000 gain

Factory Default

+1.0000

Minimum Value

–4.0000

Maximum Value

+4.0000

This word supplies the fractional part of the
external velocity reference 2 when the ex-
ternal velocity control has been selected in
Logic Command (P52).

This word supplies the whole number refer-
ence 2 when the external velocity control
has been selected in Logic Command
(P52).

This parameter sets the gain multiplier that
will be used to scale velocity reference 2.

This word supplies the fractional number
part of a 32 bit velocity reference trim.

Velocity Trim Hi (32 bit)
[Vel Trim Hi]

Parameter Number

107

Parameter Type

Sink

Display Units

+/– x.x rpm

Drive Units

4096 = Base Motor Speed

Factory Default

0.0 rpm

Minimum Value

– 8 x Base Speed

Maximum Value

+ 8 x Base Speed

This word supplies the whole number part
of a 32 bit velocity reference trim.

Velocity Reference Testpoint Data LOW
[Vel Ref TP Low]

Parameter Number

108

Parameter Type

Source

Display Units

x

Drive Units

1 = 2

1

/

28

Base Motor Speed

Factory Default

0

Minimum Value

0

Maximum Value

65535

Velocity Reference Testpoint Data HI
(32 bit)
[Vel Ref TP Hi]

This parameter indicates the LOW of the
32 bit value of the internal location selected
by the Vel Ref TP Sel, (P110).

Parameter Number

109

Parameter Type

Source

Display Units

+/– x.x rpm

Drive Units

4096 = Base Motor Speed

Factory Default

+0.0 rpm

Minimum Value

–8 x Base Speed

Maximum Value

+8 x Base Speed

This parameter indicates the HI 32 bit
value of the internal location selected by
the Vel Ref TP Sel, (P110).

Advertising