Chapter 4

Startup

4–33

Serial Communications Module:

The following figure shows how the I/O image table for the programmable
controller relates to the 1336 FORCE drive when a Serial Communications
Module is used.

1203–Gx2

DF1/DH485 to SCANport

N40:0–63

BTW Emulation

N41:0

Logic Command

N41:1

Reference

N41:2

Datalink A1

N41:3

Datalink A2

N41:4

Datalink B1

N41:5

Datalink B2

N41:6

Datalink C1

N41:7

Datalink C2

N41:8

Datalink D1

N41:9

Datalink D2

1336 FORCE Drive

PLC, SLC,

or PC

DF1/DH485

Serial Messages

(Write)

DF1/DH485

Serial Messages

(Read)

Message Handler
Logic Evaluation Block
SP An 2 Sel (p. 367)
Data In A1 (p. 310)
Data In A2 (p. 311)
Data In B1 (p. 312)
Data In B2 (p. 313)
Data In C1 (p. 314)
Data In C2 (p. 315)
Data In D1 (p. 316)
Data In D2 (p. 317)

Message Handler
Logic Status Low (p. 56)
SP An Output (p. 379)
Data Out A1 (p. 320)
Data Out A2 (p. 321)
Data Out B1 (p. 322)
Data Out B2 (p. 323)
Data Out C1 (p. 324)
Data Out C2 (p. 325)
Data Out D1 (p. 326)
Data Out D2 (p. 327)

N40:0–63

BTR Emulation

N41:0

Logic Status

N41:1

Feedback

N41:2

Datalink A1

N41:3

Datalink A2

N41:4

Datalink B1

N41:5

Datalink B2

N41:6

Datalink C1

N41:7

Datalink C2

N41:8

Datalink D1

N41:9

Datalink D2

SCANport

Optionally enabled using

DIP switches on the adapter.

Advertising