File 2 – communications i/o – Rockwell Automation 1336T FORCE Series B User Manual

Page 151

Advertising
background image

Chapter 5
Programming Parameters

5–25

File 2 – Communications I/O

Channel A Group

Logic Group

Analog Input Group

Analog Output Group

CntrlNet In 0

322

ChA Logic Cmd In

367

Analog In 1

339

Analog Out 1

387

CntrlNet In 1

323

Logic Command

52

An In 1 Offset

392

An Out 1 Offset

400

CntrlNet In 2

324

Logic Status Low

56

An In 1 Scale

393

An Out 1 Scale

401

CntrlNet In 3

325

Logic Status Hi

57

Analog In 2

340

Analog Out 2

388

CntrlNet In 4

326

Logic Options

59

An In 2 Offset

394

An Out 2 Offset

402

CntrlNet In 5

327

An In 2 Scale

395

An Out 2 Scale

403

CntrlNet In 6

328

Analog In 3

341

Analog Out 3

389

CntrlNet In 7

329

An In 3 Offset

396

An Out 3 Offset

404

CntrlNet Out 0

351

An In 3 Scale

397

An Out 3 Scale

405

CntrlNet Out 1

352

Analog In 4

342

Analog Out 4

390

CntrlNet Out 2

353

An In 4 Offset

398

An Out 4 Offset

406

CntrlNet Out 3

354

An In 4 Scale

399

An Out 4 Scale

407

CntrlNet Out 4

355

SP Analog In

338

SP Analog Out

386

CntrlNet Out 5

356

SP Analog Sel

391

CntrlNet Out 6

357

CntrlNet Out 7

358

Drv – Drv

Fault Sel/Sts

SCANport Owners

SCANport Masks

SCANport I/O

D2D Tsk Interval

9

SP Fault Sts

442

Stop Owner

369

Port Enable Mask

408

Data In A1

314

D2D Baud Rate

10

SP Warn Sts

443

Start Owner

371

Start Mask

410

Data In A2

315

D2D Xmit Addr

11

SP Fault Sel

440

Jog1 Owner

372

Jog Mask

411

Data In B1

316

D2D Xmit Ind 1

14

SP Warn Sel

441

Jog2 Owner

373

Direction Mask

409

Data In B2

317

D2D Xmit Data 1

20

ICN Fault Sel

425

Direction Owner

370

Reference Mask

412

Data In C1

318

D2D Xmit Ind 2

15

ICN Warn Sel

426

Set Ref Owner

374

Local Mask

415

Data In C2

319

D2D Xmit Data 2

21

CP Flt Status

82

Local Owner

375

Clear Fault Mask

413

Data In D1

320

D2D Rcv 1 Addr

12

VP Flt Status

83

Flux Owner

376

Reset Drive Mask

414

Data In D2

321

D2D Rcv 1 Ind 1

16

CP Warn Status

84

Trim Owner

377

Data Out A1

343

D2D Rcv 1 Data 1

22

VP Warn Status

85

Ramp Owner

378

Data Out A2

344

D2D Rcv 1 Ind 2

17

CP Fault Select

86

Clr Fault Owner

379

Data Out B1

345

D2D Rcv 2 Data 2

23

CP Warn Select

87

Data Out B2

346

D2D Rcv 2 Addr

13

VP Fault Select

88

Data Out C1

347

D2D Rcv 2 Ind 1

18

VP Warn Select

89

Data Out C2

348

D2D Rcv 2 Data 1

24

Ncfg Flt Status

81

Data Out D1

349

D2D Rcv 2 Ind 2

19

PwrUp Flt Status

80

Data Out D2

350

D2D Rcv 2 Data 2

25

Max DB Power

77

Max DB Temp

78

DB Time Const

79

Shaded parameters are Standard 1336 FORCE parameters.

Advertising