Rockwell Automation 1336T FORCE Series B User Manual

Page 176

Advertising
background image

Chapter 5
Programming Parameters

5–50

Maximum Forward Speed Trim
[Max Fwd Spd Trim]

Parameter Number

130

Parameter Type

Sink

Display Units

+/– x.x rpm

Drive Units

4096 = Base Motor Speed

Factory Default

+ Base Speed

Minimum Value

+ 0.0 rpm

Maximum Value

+ 6 x Base Speed

This parameter limits the maximum value
of the velocity reference after the process
trim.

Droop Percent
[Droop Percent]

Parameter Number

131

Parameter Type

Sink

Display Units

x.x%

Drive Units

Display units x 10

Factory Default

0%

Minimum Value

0%

Maximum Value

25.5%

This parameter specifies the percent of
base speed that the velocity reference will
be reduced when at full load torque. This
feature can be used to cause motor veloc-
ity to droop with an increase in load.

Velocity Reference Output LOW
[Vel Ref Out Low]

Parameter Number

132

Parameter Type

Source

Display Units

x

Drive Units

None

Factory Default

0

Minimum Value

0

Maximum Value

65535

Velocity Reference Output HI (32 bit)
[Vel Ref Out High]

Parameter Number

133

Parameter Type

Source

Display Units

+/– x.x rpm

Drive Units

4096 = Base Motor Speed

Factory Default

+0.0 rpm

Minimum Value

– 8 x Base Speed

Maximum Value

+ 8 x Base Speed

This is the low word portion of a 32 bit
velocity reference quantity. It is the input
term for the Velocity PI Regulator.

This is the high word portion of a 32 bit ve-
locity reference quantity. It is the input
term for the Velocity PI Regulator.

Velocity Regulator Output
[Vel Reg Output]

Parameter Number

134

Parameter Type

Source

Display Units

+/– x.x %

Drive Units

4096 = 100.0% Iq motor

Factory Default

+ 0.0 %

Minimum Value

– 300.0%

Maximum Value

+300.0%

This parameter represents the torque refer-
ence value that appears at the output of
the Velocity PI Regulator. It is the input to
the torque mode selector and is used as
the drive’s torque reference value when in
torque mode 1.

Velocity Regulator Testpoint Data
LOW
[Vel Reg TP Low]

Parameter Number

135

Parameter Type

Source

Display Units

x

Drive Units

None

Factory Default

0

Minimum Value

0

Maximum Value

65535

Velocity Regulator Testpoint Data HI
(32 bit)
[Vel Reg TP Hi]

Parameter Number

136

Parameter Type

Source

Display Units

+/–x

Drive Units

None

Factory Default

0

Minimum Value

–32767

Maximum Value

+32767

This parameter indicates the value of the
internal location selected by the Velocity
Regulator Testpoint Select parameter,
P137. The select allows this parameter to
be used as a testpoint for the velocity
regulator.

This parameter indicates the value of the
internal location selected by the Vel Reg
TP Sel parameter, P137. The select allows
this parameter to be used as a testpoint for
the velocity
regulator.