Chapter 4
Startup

4–7

or

or

Quick Start Procedure

Choose Mode
Startup

Choose Mode
Display

Base Motor HP
30.0 HP

Setup Motor
Nameplate N

1. An automated Quick Startup sequence is

available on the HIM to lead you through all
data entry, configuration and diagnostic tests
that must be performed when starting up the
1336 FORCE drive.

From the Status Display, press Enter (or
any key). “Choose Mode” will be
shown.

Press the Increment (or Decrement) key
until “Startup” is displayed. Press Enter.

The “Setup Motor Nameplate” display
will appear.

If you have not previously entered the
Motor Nameplate data toggle to the Yes
(Y) selection in the Setup Motor
Nameplate display and press Enter.

The first motor informational screen
will appear. Use the Select key to
access the second line and make any
changes with the Increment and Decre-
ment keys. In subsequent displays you
will be asked to provide the following
motor information:
1. Base Motor Current
2. Base Motor Volts
3. Base Motor Frequency
4. Motor Poles
5. Base Motor Speed
6. Feedback Device Type

When all motor and feedback data have
been entered, a display asking you if
you wish to run the Motor Connect
Diagnostics will appear. Press the Enter
key to initiate the test sequence. In
subsequent displays you will be asked if
you wish to run the following tests:
1. Inverter Diagnostics
2. Motor Rotation Test
Press the green Start key to run the
diagnostic test.
Press the red Stop key when the Motor
Rotation Test has completed.

or

Motor Connect
Diagnostics? Y

Transistor Diag
Press START!

Check Motor
Rotation? Y

Advertising