Rockwell Automation 1336T FORCE Series B User Manual

Page 192

Advertising
background image

Chapter 5
Programming Parameters

5–66

Testpoint Data #1
[Torq TP Sel 1]

Parameter Number

274

Parameter Type

Source

Display Units

+/– x

Drive Units

None

Factory Default

0

Minimum Value

–32767

Maximum Value

32767

Testpoint Selection #2
[Torq TP Sel 2]

Parameter Number

275

Parameter Type

Sink

Display Units

x

Drive Units

None

Factory Default

0

Minimum Value

0

Maximum Value

100

Testpoint Data #2
[Torq TP Data 2]

Parameter Number

276

Parameter Type

Source

Display Units

+/– x

Drive Units

None

Factory Default

0

Minimum Value

–32767

Maximum Value

32767

Testpoint Selection #3
[Torq TP Sel 3]

Parameter Number

277

Parameter Type

Sink

Display Units

x

Drive Units

None

Factory Default

0

Minimum Value

0

Maximum Value

100

Testpoint Data #3
[Torq TP Data 3]

Parameter Number

278

Parameter Type

Source

Display Units

+/– x

Drive Units

None

Factory Default

0

Minimum Value

–32767

Maximum Value

32767

Testpoint Selection #4
[Torq TP Select 4]

Parameter Number

279

Parameter Type

Sink

Display Units

x

Drive Units

None

Factory Default

0

Minimum Value

0

Maximum Value

100

Testpoint Data #4
[Torq TP Data 4]

Parameter Number

280

Parameter Type

Source

Display Units

+/– x

Drive Units

None

Factory Default

0

Minimum Value

–32767

Maximum Value

32767

This parameter contains the data selected
by Testpoint Selection #1 (param 273).

This parameter selects a torque block test
point. The value of that test point can be
read from Testpoint Data #2 (Parm 276).

This parameter contains the data selected
by Testpoint Selection #1 (param 275).

This parameter selects a torque block test
point. The value of that test point can be
read from Testpoint Data #3 (Parm 278).

This parameter contains the data selected
by Testpoint Selection #3 (param 277).

This parameter selects a torque block test
point. The value of that test point can be
read from Testpoint Data #4 (Parm 280).

This parameter contains the data selected
by Testpoint Selection #4 (param 279).

Advertising