Chapter 6
Troubleshooting

6–35

The Hardware Testpoints on the PLC Comm Adapter Board are illustrated in
Figure 6.12. The accompanying table details the expected output from each
testpoint.

Figure 6.12
PLC Comm Board Test Points

AP
Status

LANGUAGE
MODULE

DP Status

1

CH A High

J5


TP1

Port 1

DOMINO
ADAPTER

RIO
Channel A

Communication Modes

U2

U3

U4

U5

10

TB20

TB21

1

19

CH A Low

CH B Low

CH B High

D3

D6

D8

D10

D12

D13

D14

D15

CH A
Status

CH B
Status

J7

D1

D2

Port 2


TP2


TP3


TP4


TP5

ADC Inputs

DAC Inputs

J1

Main Control
Interface

Drive Permissives

J4

J3

120 V

RIO
Channel B

BRAM
Enable

Ref

D4

D5

Fault Out

Ext Fault

D7

Norm Stop

Motor Thermo

D9

Drive Enable

D11

24 V

120 V

24 V

120 V

24 V

120 V

24 V

J11

J10

J9

J8

Drive En

M Therm

N Stop

X Flt

EN

DIS

Fuse
1 – 4

TP24

+10V Ref

TP25

–10V Ref

ON

ON

ON

ON

DGND +5V

+15V

–15V

AGND


TP9 TP10 TP11 TP12 TP13 TP14

TP19

TP20 TP21 TP22 TP23

TP15 TP16 TP17 TP18

TP1

TP2

TP3

TP4

TP5

TP9

TP10

TP11

TP12

TP13

TP14

Testpoint

DGND

+5V

+15V

AGND

–15V

Not Used

Not Used

ISO +12 VDC

ISO –5V

ISO GND

IGND

Application

TP15

TP16

TP17

TP18

TP19

TP20

TP21

TP22

TP23

TP24

TP25

Testpoint

AIN – 1

AIN – 2

AIN – 3

AIN – 4

+12V

AOUT – 1

AOUT – 2

AOUT – 3

AOUT – 4

+10V Ref

–10V Ref

Application