FILE 4 – Diagnostics

Monitor

8
147
148
149
167
168
182
185
186
264
265
266
268
269
270
271

Motor Control Counter
Scaled Velocity Fdbk
Enc Pos Fdbk Lo
Enc Pos Fdbk Hi
Internal Torque Fdbk
Internal Iq Ref
Computed Power
Perunit Motor Current
Perunit Motor Voltage
Motor I Magn. Fdbk
Motor Volt Magn.
Stator Frequency
DC Bus Voltage
Filtered Vel Fdbk
Inverter Temp Fdbk
Limited Motor Flux

Figure 5.3. PLC Comm Adapter Parameters (cont.)

Testpoints

AT Testpt Data
AT Testpt Sel
Logic Testpt Data
Logic Testpt Sel
Fault Testpt Data
Fault Testpt Sel
Velocity Ref Testpt Lo
Velocity Ref Testpt Hi
Velocity Ref Testpt Sel
Velocity Reg Testpnt Lo
Velocity Reg Testpnt Hi
Velocity Reg Testpt Sel
Vel Fdbk Testpt Lo
Vel Fdbk Testpt Hi
Vel Fdbk Testpt Sel
Torque Ref Tespt Data
Torque Ref Testpt Sel
Torque Testpt Select
Torque Testpt Data

Transistor Diag

Info

59
256
257
258
259
260
261

1
5
220
221
300
301
302
303
304
305
306
307
309

Drive Software Ver
Power Structure Type
Rated Inverter Out Amps
Rated Inverter In Volts
Adapter ID
Adapter Version
Adapter Config
ChA Dip Switch
ChB Dip Switch
ChA LED State
CHB LED State
PLC Comm Bd Sts
Language Select

47
48
70
71
98
99
108
109
110
135
136
137
143
144
145
172
173
273
274

Fault Select/Status

77
78
79
80
81
82
83
84
85
86
87
88
89
425
426
430
431
436
437
438
439
440
441
442
443

Max Dyn Brake Pwr
Max Dyn Brake Temp
Max Dyn Time Const
Pwrup Flt sts
Non–config sts
CP Flt Status
VP Flt Status
CP Warn Status
VP Warn Status
CP Flt Select
CP Warn Select
VP Flt Select
VP Warn Select
ChA Flt Sel
ChA Warn Sel
ChB Flt Sel
ChB Warn Sel
ChA Flt Status
ChA Warn Status
ChB Flt Status
ChB Warn Status
SP Flt Select
SP Warn Select
SP Warn Sts
SP Warn Sts

Logic Options
AT Diag Select
Trans Diag Config
Inv. Dig. Result 1
Inv. Diag. Result2
Iq Offset
Id Offset

Trend I/O*

454
462
463
464
472
473
474
482
483
484
492
493

Trend In 1
Trend In 1 Status
Trend Out 1
Trend In 2
Trend In 2 Status
Trend Out 2 Status
Trend In 3
Trend In 3 Status
Trend Out 3
Trend In 4
Trend In 4 Status
Trend Out 4

Trend Setup*

455
456
457
458
459
460
461
465
466
467
468
469
470
471
475
476
477
478
479
480
481
485
486
487
488
489
490
491

Trend 1 Operand X
Trend 1 Operand Y
Trend 1 Operator
Trend 1 Rate
Trend 1 Post Samples
Trend 1 Continuous Trig
Trend 1 Select
Trend 2 Operand X
Trend 2 Operand Y
Trend 2 Operator
Trend 2 Rate
Trend 2 Post Samples
Tr2 Cont Trigger
Trend 2 Select
Trend 3 Operand X
Trend 3 Operand Parm Y
Trend 3 Operator
Trend 3 Rate
Trend 3 Post Samples
Trend 3 Continuous Trig
Trend 3 Select
Trend 4 Operand X
Trend 4 Operand Y
Trend 4 Operator
Trend 4 Rate
Trend 4 Post Samples
Trend 4 Continuous Trig
Trend 4 Select

*Note: Trending Functions are NOT implemented in Version 2.xx software.