Setting speeds and acceleration – Hypertherm V9 Series Phoenix Rev.11 User Manual

Page 105

Advertising
background image

Phoenix 9.76.0 Installation and Setup Manual 806410

105

3 – Torch Height Control Axis Setup

c. Choose the analog input to use for arc voltage feedback:

EDGE Pro: Analog 5 for THC1, Analog 6 for THC2

MicroEDGE Pro: Analog 5 for THC1, Analog 6 for THC2

EDGE Pro Ti: Analog 3 for THC1

Note: If you have a SERCOS model of the EDGE Pro or MicroEDGE Pro, refer to the SERCOS Setup section
in this manual for information on setting up the Sensor THC.

Setting speeds and acceleration

After you select the Sensor THC in the Machine screen, set the speed and acceleration settings on the Machine Setups
> Speeds screen. The following screen shows the recommended speeds for the Hypertherm lifter and drive
(ASSY-0177).

Advertising