Phoenix 9.76.0 Installation and Setup Manual 806410

7 – Plasma Setup

Lower Torch / Lower All Torches Activates the Torch Down output while it is on. The Lower Torch inputs can be

connected to manual toggle switches on the operator console.

Raise Torch / Raise All Torches Activates the Torch Up output while it is on. The Raise Torch inputs can be connected

to manual toggle switches on the operator console.

Torch Down Sense When this input turns on, the CNC turns off the Torch Down output. This input is not used with the

Sensor THC.

Torch Up Sense When this input turns on, the CNC turns off the Torch Up output. This input is used as an upper limit

switch for a torch lifter. This input is not used with the Sensor THC.

Torch Down This output signals the cutting station to lower the torch. Use the Torch Down Time on the Process screen

to specify the number of seconds for the torch to be lowered. The Torch Down output turns off before the
Torch Down Time elapses if the Torch Down Sense input activates. This output is not used with the Sensor
THC.

Torch Up This output signals the cutting station to raise the torch. Use the Full Torch Up Time or Partial Torch Up Time on

the Process screen to specify the number of seconds to raise the torch. The Torch up output turns off before
the Full or Partial Torch Up Time elapses if the Torch Up Sense input activates. This output is not used with
the Sensor THC.

Summary: setting up the plasma routine

1. Select the Plasma 1 and Plasma 2 processes in the Special Setups screen.

2. Select a marking process if the plasma torch will be used as a marker.

3. Assign the inputs and outputs for the plasma supply on the I/O setup screen.

The I/O assignments for the plasma supply depend on the number of torches and whether the CNC will be
operating all the torches independently.

For the CNC to operate each torch independently, numbered outputs and station select inputs must be assigned
in the I/O setup screen. Refer to

Section 4 Station Setup for numbered I/O and Station Select inputs.

4. Define timer settings and other cutting parameters in the Process screen.