Sensor thc axis screen, Station configuration screen – Hypertherm V9 Series Phoenix Rev.11 User Manual

Page 117

Advertising
background image

Phoenix 9.76.0 Installation and Setup Manual 806410

117

3 – Torch Height Control Axis Setup

Sensor THC Axis screen

Station Configuration screen

For Station 1, choose the Sensor THC as the lifter.

Parameter

Setting

Proportional Gain

50

feedforward Gain

0

Derivative Gain

0

Velocity Gain

150

Integral Gain

0

Voltage Gain

40

Servo Error Tolerance

5.08 mm (0.2 inch)

Stall Force Tolerance

0.51 mm (0.02 inch)

Encoder Counter mm/in

1028.35 counts/mm

(26120 counts/inch)

Encoder Polarity

Positive

DAC Polarity

Negative

Drive Type

Current

Encoder Decode Mode

4X

Slide Length

165.1 mm (6,5 in)

Home

to Hard Stop Current Limited

Current Limit

25%

Home Current Limit

25%

IHS Current Limit

8%

Plasma Tracking Mode

Normal

Average Voltage Over

25 msec