Phoenix 9.76.0 Installation and Setup Manual 806410

13 – Phoenix Link

Communications Time Out

This message is displayed if the specified amount of time allowed for a response from the host computer expires. This
amount of time is configured in the Link setup screen. There could be a fault in the cable connection, cable configuration,
or the host computer’s communications port.

Checksum Error

This message is displayed at the CNC after a part has been uploaded or downloaded if the checksum calculated by the
host and the CNC do not match. The checksum calculation is performed by adding the numeric values of the ASCII
codes that are used. Possible reasons for this error are incorrect cabling or transmission at a speed that is too high for
the selected communications system.

Warning: The Master Folder Selected does not Contain any Folders

This error message is displayed at the host computer if the selected master folder does not contain any subfolders. You
can choose to add subfolders if they do not exist. If subfolders do exist, the path to the master folder may be incorrect.

For additional assistance in trouble shooting the Phoenix Link in the event of a failure, contact your CNC vendor.