LAN and Hypernet Tests

The LAN and Hypernet tests both use the same tester.

Conduct this test if:

The CNC is not communicating to the ArcGlide or plasma system.

The CNC is not communicating to the local area network.

To test a LAN port:

1. On the Machine Interface screen, choose the LAN or Hypernet port.

2. Follow the instructions on the screen to plug in the tester.

3. On the Machine Interface screen, choose Test. A message informs you if the test is successful.

If either test fails, contact your OEM or system integrator to replace the motherboard.

Operator Interface Test

The operator interface test verifies that the front panel of an EDGE Pro CNC is operating correctly.

Perform this test if any function on the integrated operator console is not working as expected.

Note: None of the components on the screen allow motion or any action to take place on the CNC or cutting table.