Phoenix 9.76.0 Installation and Setup Manual 806410

2 – Machine Setup

In the following illustration, the Torch Height Disable output is activated based on the values of the setup parameters.

For these values, the Torch Height Disable output is active

1

2.7 mm (0.5 inches) before and 2.7 mm (0.5 inches) after

each 90 degree corner. This output is also activated as the torch accelerates away from the pierce and through the arc
because the speed is below the Torch Height Disable Speed value. Finally, because the arc intersects at greater than the
20-degree tangent angle, the Torch Height Disable output is activated for 0.5 inches before and after the beginning of
the arc, and is activated for 0.5 inches before and after the end of the arc.

Parameter

Value

Torch Height Disable Speed Percentage value

90%

Distance Before THC Speed value

12.7 mm (0.5 inches)

Distance After THC Speed value

12.7 mm (0.5 inches)

Tangent Angle Value

20 degrees