Hypertherm V9 Series Phoenix Rev.11 User Manual

Page 272

Advertising
background image

272

Phoenix 9.76.0 Installation and Setup Manual 806410

15 – Oxyfuel Application

Controlling proportional gas regulators with analog outputs

Hypertherm CNCs provide analog outputs that can control proportional gas regulators. Using this strategy allows you to
reduce the number of regulators needed for the gas delivery system from six as shown earlier in this section, to three as
shown below. Analog outputs are available for three channels: fuel gas, preheat oxygen, and pierce/cut oxygen.

Setting up your oxyfuel cutting system in this manner requires a SERCOS drive system to control the extended number
of analog outputs.

High preheat fuel

Fuel gas

supply

Oxygen gas

supply

Preheat oxygen

Cut and pierce oxygen

Bleed-off fuel

Bleed-off preheat oxygen

Fuel gas

Preheat oxygen

Cut and pierce oxygen

Gas solenoid valve, normally closed

Manual pressure regulator

Flow control valve

Torch 2

Torch 1

Each torch has its own supply lines:

Cut oxygen 1 and 2

Preheat oxygen 1 and 2

Fuel 1 and 2

Bleed-off cut oxygen