Phoenix 9.76.0 Installation and Setup Manual 806410

175

7 – Plasma Setup

Temperatures: Current temperature readings for the chopper, coolant, transformer, and inductors. If any one of these

temperatures exceeds a maximum threshold, it will display in red. When this occurs, the plasma power
supply cannot be operated until the condition is resolved.

Plasma: Plasma gas pressure. The Set value shows the gas pressure reported by the power supply. The Measured value

displays as zero by default, but you can watch the values in this field to monitor the plasma gas pressure
when you activate the diagnostic modes on the screen.

Shield: Shield gas pressure. The Set value shows the gas pressure reported by the power supply. The Measured value

displays as zero by default, but you can watch the values in this field to monitor the shield gas pressure when
you activate the diagnostic modes on the screen.

Flow Gas Set Pressure: Diagnostic mode used to determine if the gas pressure set for the power supply can be

achieved and maintained. Select this soft key to activate the diagnostic mode, then select it again to
deactivate it.

You can also select the Cancel or OK soft key at any time to end the current diagnostic
mode and exit the Diagnostic screen.

Plasma Leak Check: Diagnostic mode used to determine if the valve in the plasma line is functioning properly to trap

the gas in the line and maintain a steady pressure. Select this soft key to activate the diagnostic mode, then
select it again to deactivate it.

Flow Gas Full Pressure: Diagnostic mode used to determine the highest gas pressure that can be maintained. Select

this soft key to activate the diagnostic mode, then select it again to deactivate it.

For the Flow Gas Set Pressure and Flow Gas Full Pressure diagnostic modes, gas will
continue to flow until you stop the diagnostic mode.

In-line Valve Check: Diagnostic mode used to determine if the valve in the plasma line is opening and closing properly

and is allowing the gas to exit the line. Select this soft key to activate the diagnostic mode, then select it
again to deactivate it.

System Reset: Reset key used to reset the power supply system, if needed.

For a more detailed explanation of the diagnostic modes on this screen and for possible
corrective actions, refer to the “Operation” section in the

MAXPRO200 Instruction

Manual (807700).