15 – oxyfuel application – Hypertherm V9 Series Phoenix Rev.11 User Manual

Page 263

Advertising
background image

Phoenix 9.76.0 Installation and Setup Manual 806410

263

15 – Oxyfuel Application

To start the oxyfuel cut sequence, select Oxyfuel Cut Mode on the Main screen, load a part file, and press Cycle Start.
The torch moves to the first pierce point in the program.

The M07 code (Cut On) runs in the part program. Torch Down output turns on.

Torch Down output remains on until either the Primary Torch Down Time elapses or the Torch Down Sense input
turns on.

Status Message:

Lowering Torch

Ignition output turns on.

Ignition output remains on until the Ignition Time expires.

Status Message:

Igniting Torch

Low Preheat Control output turns on if Low Preheat Time is used.

This output may already be on because the Low Preheat Select input was turned on at the beginning of the
sequence.

Low Preheat Control output remains on until the Low Preheat Time elapses

.

Status Message:

Low Preheat

High Preheat Control output turns on.

The preheating of the workpiece occurs to prepare for piercing.

High Preheat Control output remains in this state until the High Preheat Time elapses or you press Cycle Start. Cycle
Start bypasses preheats and allows manual control of piercing.

To have the High Preheat Control output remain on while piercing

and cutting, set Preheat During Cut to Yes on the

Oxyfuel Process screen. Use this option if the oxyfuel torch requires high pressure fuel gas for cutting.

Status Message:

High Preheat

Pierce Control Output turns on.

Pierce Control output activates the pierce-oxygen channel.

The Pierce Control output can be used to decrease the preheating time of the workpiece.

Pierce Control remains on until the Pierce Time elapses.

High Preheat Control remains on if Preheat During Cut is active.

Low Preheat remains on.

Status message:

Piercing

Cut Control output turns on during piercing.

The Cut Control output activates the cut-oxygen channel.

The Cut Control output turns on after the Cut Control Delay time elapses. This timer allows the Pierce Control output
time to start piercing the workpiece. Then Cut Control turns on to provide a boost by turning on the cut-oxygen
channel.

Status message:

Piercing