Oxyfuel inputs – Hypertherm V9 Series Phoenix Rev.11 User Manual

Page 266

Advertising
background image

266

Phoenix 9.76.0 Installation and Setup Manual 806410

15 – Oxyfuel Application

Oxyfuel inputs

Oxyfuel inputs can be used for switches on an operator console to control the oxyfuel cutting system. The screen below
shows an example of input assignments for an oxyfuel cutting system with two torches.

Low Preheat Select: This input can be used as an oxyfuel on/off switch on the operator console of the CNC (a

momentary push-button or a single-pole, single-throw (SPST) toggle switch). This input turns on the Low
Preheat output while the switch remains in the ON position. With this input on, low pressure fuel gas will be
delivered to the torch, and can be manually adjusted.

Cut Select: This input can be used as an ON/OFF switch on the operator console of the CNC (a momentary

push-button or SPST toggle switch). This input turns on the Cut Control output while the switch remains in
the ON position. With this input on, high pressure oxygen will be delivered to the torch and can be manually
adjusted.

High Preheat Select: This input can be used as an ON/OFF switch on the operator console of the CNC (a momentary

push-button or SPST toggle switch). This input turns on the High Preheat output while the switch remains in
the ON position With this input ON, high pressure fuel gas will be delivered to the torch and can be manually
adjusted.

Manual Ignition Select: This input can be used as an ignition switch (a momentary push-button) on the operator

console of the CNC. It turns on the ignition output while the input is ON. This input can also be used to
manually turn on the ignitors.

Lower Torch / Lower All Torches: This input can be a toggle switch that turns on the Torch Down output. The Torch

Down output signals the oxyfuel torch lifter to lower the torch.

Advertising