Hypertherm V9 Series Phoenix Rev.11 User Manual

Page 183

Advertising
background image

Phoenix 9.76.0 Installation and Setup Manual 806410

183

8 – Diagnostics

2. Follow the instructions on the screen to connect the HyPath (green) or Picopath (orange) test plug to the I/O port

you selected on the back of the CNC.

3. On the Machine Interface screen, press Test. A message informs you if the test is successful.

4. If the test fails, follow the instructions on the screen to connect the test HyPath (red) or Picopath (white) test plug to

isolate the input or output point that is causing the problem.

5. On the Machine Interface screen, press Test. The screen reports the number of the failed input or output.

Picopath: Rewire the I/O to a few I/O point, then reassign the input function in the phoenix software.

Hypath:

If an input has failed, rewire the input to a free input point, then reassign the input function in the Phoenix
software.

If an output has failed, you can remove a relay from a spare output and swap it with the relay at the failed output.
No rewiring is required.

Advertising